why do 4 mA serves as 0% not 0 mA?

Answer Posted / s hasini

TO MEASURE THE INSTRUMENTAL ERROR

Is This Answer Correct ?    1 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

the pump holds on run indication into the dcs and filed local control panel remote push button condition operaton wrong like when the push button pushing conditions the pump is off and the push button release condition the pump is on totally opposite condition . And control room inside give the stop command into dcs just 1secon relay engage and again normal condition. How can I slove

1134


I installed the smartplant instrument v8, but can not be opened, that always said: "INTools 2007 hardlock no found". So Could you help me how to do for that?

1645


please can any one tell me clearly about pid tuning i am confusing about this .how to tune pid easly?

1689


while i check zero check for dp flow transmitter some fluctuating came (0 to 458 kg/h) what is the reason?

1347


How is work 5/2 sov?

1385






what is the different between deflection type measurement and null type measurement in RTD?

1453


Which is your favourite subject & explain any one topic of it.

8997


1.what is the effect of vapour presuure in orifice plate flow measurement 2.which is more effective 2 pressure sensors or one single differential pressure sensor in orifice plate measurement 3.how to design a v/i converter and i/v converter 4.how many type of thermocouple are there 5.how many leads are there in thermocouple measurement 6.how pressure sensors are connected in level measurement in differential pressure method 7.what is the output of capacitive pressure sensor (ac or dc),how its o/p is signal charactarized 8.what is the physical meaning of discharge coeeficient,why it is calculated,orifice plate what is its value,why it is less than 1,Q at upstream is equal to or not equal to Q at downstream of orifice plate why?what is vena contracta in orifice plate 9.why rotameter is called variable area flowmeter,it can measure flow even if area is not varying,why it is made tapered 10.design a 10 bit counter ,which counter you will prefer 11.how to remove self heating error in RTD 12.which is more sensitive pt100 or pt50 13.why thermocouple are connected in parallel 14.what is lead contact error in RTD,how to avoid 15.what is P,PI,PID,PD controller,why there is no ID controller 16.what is override,split range,sequential,ratio,feedforward,cascade controller 17.why we moved from SR to JK and then JK to master slave JK flipflop,give correct reason 18.how to measure level of a closed container which contains vapour and liquid,remember no vapour gas should be leaked,so ultrasonic and capacitive is not an option,design another method 19.how to design horse race counter including sensors and signal conditioning element 20.what is bevelling

1960


If fire would be inside the plant which fire detector is to detected the fire.

1076


Draw a group of instruments interlocked to a Pump & Motor?

654


how u calibrate pneumatic n motorized c/v?

1535


how to change measuring units from mmwc to cubm/h in rosemount air flow transmitter with hart communicator fluke 744

1926


what is stroke check for field instument transmetter's & AOV's

1728


what is the vital subject for scoring bhel exam&what is the question pattern

1886


our kks tagging is crossing more than 12 character please suggest how to take tags in the DCS

1669