what is meant by magnetic flow meter ? explain its working
principle ?

Answer Posted / rajesh

it consist of a turbine impeller mounted on a shaft which is
connected to a miniature dc motor . as fluid passes through
turbine , it rotates and velocity of fluid is proportional
to turbine speed . hence if we connect a voltmeter we get
flow reading . it is ideally a active transducer , but since
all fluids have different parameters a small voltage is
applied to turbine , but principle is same

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how external lighting design? please give examples?

1427


A 500 V shunt motor runs at its normal speed of 250rpm when the armature current is 200A. The resistance of the armature is 0.12 Ω. Calculate the speed when a resistance is inserted in the field reducing the shunt field to 80% of normal value and the armature current is 100A.

2024


How to measure the Harmonic Distortion of UPS ie THD?

1738


i need the details about bhel exam.how to apply for that.please send to my email-id.thenmozhi2k7@gmail.com

1539


what will happen if ac and dc supplies given

1653






how ceiling fan worked?

1491


Distribution transformer we provided 2 separate earthing pit for Body and 2 separate earthing pit for neutral,we can not connect separate body earthing pit to other earthing pit but we do metal glanding in secondary side cable termination in both side, transformer and PCC panel (LT Panel), is this safe for transformer and other equipment?

1253


in dc shunt motor if field winding is shorted then

1369


Has someone here done a sizing for a generator (3 phase), its for a pumping station. If you have an example for standby/duty and both running (I) star delta (ii) Soft Starter.

1620


how to size H.T & L.T Panel ?

1642


We are designer please help me calculate the size of 11kv cables from step up transformer to M.V panel, total load is 5 mega watt distance 900 feet (used aluminum type cables) please provided formula for calculate the cable with example.

1215


we specify current in case of feeder but in case of distributor voltage, why?

1379


Hi Friend I am used multimeter to measure the voltage between R Phase(SS1) to R Phase(SS2). In SS1 is connected with UPS loads. But I am getting voltage between these 2 R Phases. Please give some idea friend

1512


what is the clear formula to calculate cable size for a load

1480


trasnfarmaer core make

1531