WHY THE FREQUENCY IS 50 HZ IN INDIA.CAN WE USE SOME OTHER
FREQUENCY.IF SO WHAT IS THE RANGE AND WHAT WILL BE THE
EFFECT IN PRESENT POWER SYSTEM IF WE CHANGE THE FREQUENCY
AS YOU SUGGEST ?

Answer Posted / jyotsna singh

in india the electrical devices are constructed for 50 hz and 230 vlot so if the frequency is chanfed we hav to chanfe the rating of the devices accordingly and as the frequency is directly proportional to the number of poles,if we increase the frequency we have to increase the number of poles also so it is not feasible

Is This Answer Correct ?    0 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

1.what is mean by 8/20 micro sec waveshape

1802


If we need 4c× 50mm sq cable but it's not available so we can pull 4c×25mm sq two cables?

939


Is it true that in the 3 phase transformer, the limbs of the core are at 45 dgrees to each other. if true, why?

1590


what is the constructional difference between a power transformer and potentian transformer?

1269


What was your role in the silicon evaluation/product ramp? What tools did you use?

1576






tan delta equation test on alternators

1775


WHAT IS SUBSTATION & ACCORDING TO VOLTAGE HT,EHT SUBSTATION EXPLAIN IT

2697


How should i design a 1ph & 3 ph transformer. Kindly let meknow all steps and formulaes related to design from scratch.

1623


salam&hi, i need to know about how can i calculate an enough current for the new building before i submit it to the suppliers

1621


When we need up only in o/p 440v, so why we use directly in 11kva in input?

1279


what is induction furnance? how many phase supply given io its coil for 15 or 20 ton furnance?

2657


what are problems caused by the pdu in rack server

1464


Define conversion efficiency of a power amplifier. What is its value for class c power amplifier?

790


Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.

1663


if we look on phasor of the transformer vaoltage is 180 oppsite at primary and the secondary so to improve a power factor is secondary should kept negative to improve it primary side means is -.90 became +.90 at other side

1396