which gas or which liquid is filled in capillary of dial
type temperature indicators on power transformers
Post New Answer View All Answers
Describe a time when you anticipated potential problems and developed preventive measures.
where are following valves are applicable to install. can any valve be installed any line. globe valve butterfly valve boll valve gate valve
i want to find out iffco get test paper
In control valve proximity inductive sensor is taken as digital feedback for full open and full close.Normally its volts 24v when the sensor acts the feed back voltage 14v so that our relay not indicating in plc panel . kindly give the solution.
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....
NPN transistor, SCR, Zener diode, LED, Varactor diode, Vortex meter, RTD, Resistor, Crystal
In dcs panel we are using diff type of modules ?what is module ? what is the use of modules ?diff type of module?
how can i calibrate the temperatuture gauge used by temperature bath(dry block) i mean step by step procedure?
what are procedure of sox-nox calibration
How we calculate orifice plat size???
What is difference between ESD and PLC please Explain me clearly.
what is exact time to study dcs and plc cources
which type of signal used in instrument?
How to calibration a control valve?