Answer Posted / aliya haider

Foundation Fieldbus is an all-digital, serial, two-way communications system that serves as the base-level network in a plant or factory automation environment. It is an open architecture, developed and administered by the Fieldbus Foundation.

Applications:
It's targeted for applications using basic and advanced regulatory control, and for much of the discrete control associated with those functions. Foundation fieldbus technology is mostly used in process industries, but nowadays it is being implemented in powerplants also.

Two related implementations of FOUNDATION fieldbus have been introduced to meet different needs within the process automation environment. These two implementations use different physical media and communication speeds.
H1 works at 31.25 kbit/s and generally connects to field devices. It provides communication and power over standard twisted-pair wiring. H1 is currently the most common implementation.
HSE (High-speed Ethernet) works at 100 Mbit/s and generally connects input/output subsystems, host systems, linking devices, gateways, and field devices using standard Ethernet cabling. It doesn't currently provide power over the cable, although work is under way to address this.

Is This Answer Correct ?    5 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75 The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is: WARNING: Could not connect to equalize destination. (7001) Retrying. Number of retries = 0/1 ERROR: LdXopsLoadMain: connect error 10060 ERROR: Processing terminated due to connection error. (7002) Equalization end with errors. STN0149 ---- ERROR = 2 WARNING = 1 ---- Background: >Updated the ExaOPC software on the STN from 3.60 to 3.75 >STN operating system is Windows Server 2008 R2 >HIS operating system is Windows Server 2016 Stanard Solutions attempted include: >Ensuring all IP addresses are correct and all networked devices can be pinged. >The ability to ping a device using its host name from another device ( from HIS) >Ensure both devices firewalls are disabled. >The antivirus installed on the STN is disabled. >Ensuring both devices are within the same workgroup. >Added both devices to each other's Host and LMHost files. >Running IT Security tool after changing any administrative settings.

1636


How does a single acting, spring return ball valve actually work? Does it require continuous air supply? 

1676


what is The specifications for oriface instalation

1609


How to calibrate capillary type level transmitter

1199


what is loop1 and loop2 in MTS LT?

4190






Positioner usage.

1493


hye SAM acn u send your e mail id, so that i can solve my query through e mail?

1814


why would you like to join our company

885


What is the calibration procedure of Drum level transmitter if range is 0 to -400 mmh2o in lab?

1683


Is there any relation between Artificial Intelligence and Instrumentation?

599


what is instrument philosophy

1750


How to Calibrate Level Troll in field

767


How can you add value to this Industry if offered the job?

1165


What should be the main consideration while starting the Rotating compressor when we dont know the cut in and the cut off pressure setting of the pressure switch

1698


basic connection and principle of axial shift sensor n differential sensors in tubine describes n draw......

1894