What happened when a three phase induction motor work on
two phase supply.9
Answer Posted / jayakrishnan
Motor will run as usual with some extra vibration, but the thing is that you can run the motor only with 60% of its rated, as told above the speed will not be reduce unless frequency reduces, its all slip maters,
Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
What is the physical significance of phase.. i.e. what is exactly the meaning in layman's language.. 1 phase, 3 phase etc ???
What are the properties of a resistor?
Cables Construction hi friends, 0.6/1/1.2 kV LV , DC and Control cables are concentric copper conductor what does its means and what is the use of concentric copper conductor,and are this with copper tape shield or copper screening, ? thanks
Why reactive power is needed in a power system? How is it being absorbed or delivered by alternators? For reactive power control we are changing excitation but reactive power absorbing or delivering related to stator. How these two are interlinked? i want a detailed explanation with necessary expressions and figures?
Why 1/3 is used in symmetrical components?
Is there a standard depth of gravel fill in Substation Switchyard? Please give a design/drawing. Thank you.
what is the function of bearing in dc mchine" and where it is placed
what is errection pcbs?
need to make a report. Need to choose a 3phase induction motor. Load conditions motor will operate in : Maximum Load: 30 Kw Speed: 2950 rpm Ambient temp: 20 cent Supply voltage: 440V Frequency: 50Hz need to look for the safety factor when choosing the motor, went through catalouge found a few, but dont know how to choose the safety factor allowing an extra load something above 30 KW to avoid any harm.
What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side
what kvrah y we need to take the readind of that
Explain in details how you would react to an unexpected incident when your supervisor or manager is not around to give instructions?
List out the different frequency domain specifications?
how to decide no of electrodes for 1600A LT Main incomer panel
why we are using Load factor?