Why Bently Nevada use negative voltage for vibration probes?

Answer Posted / ashok

1. Equipment needs safe
2. If cable damaged the prox- tip not to make short with
card which convert in to mA

Is This Answer Correct ?    3 Yes 11 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Difference between ultra sonic flow meter

1550


can any one tell me when ongc placement test and its forms is available????/ pls tell me if u know

1628


I want to apply for the universities in US,but i got the GRE score of (650+300=950)TOEFL 69/120.Is this score sufficient for applying universities please i am married i need to go to US because my husband didn't get H1 yet.please send me suggestion

1446


TECHNICAL/ARTITUDE

1717


how many type conductivity sensor ?

1628






How to convert Differential pressure to flow in TPH

1744


State bernoulli’s application.

666


hi,i am doing 3 year in electronic and instrumentation engineering. what type of aptitude questions will be asked in a core industries and how can i improve my skills in instrumentation?

1650


how to rectify the poor signal strength in utrasonic digtial flow meter ,model:ge digital xce868i

842


NSV type probe stands for

1966


Basically iam Instruemntation Engineer, but Iam interested in Instruments design engineering, so plz guide, is there any course, training or Softwres to become Instrument design engineer??.

1578


centrifugal compressor interlock? Tell me the parameter at which compressor will trip

2682


Define the terms Accuracy, precission, Spam, process tolerance while doing calibration of an instrument? Explaini with an example?

1564


Tr. Wiring for calibration.

1569


A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.

1685