Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Is Indian railway uses 25000v ac or dc?

Answer Posted / naresh

25kv dc

Is This Answer Correct ?    17 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to calculate the magnetizing current of ct ( 800A/1A) for Relay 64

1457


As we know diode work on both negative and positive but converting ac into DC we have to given a/c from negative of diode or positive side.please give me answer.

1695


I have one ct of ratio 3000-2000/1 Amp its knee point voltage mentioned on name plate is 500-333/30mA-50mA at Vk/2. in secondary box there is three terminal named 1S1, 1S2, 1S3 then on which terminal obtained the knee point voltage ie 1S1-1S2 OR 1S1-1S3 & also specify the knee point voltage for the ratio 3000 from name plate.

2454


What is the difference between UPS & inverter ? which UPS is better and whos got the edge ? what is the difference between & inverter ? which UPS is better and whos got the edge 12 V , 24 V , 36 V etc what are the advantages of 12 V, 24 V , 36 V etc and what are the disadvantages of 12 V, 24 V, 36 V etc thanks

1909


how can you size an automatic voltage regulator?

2366


in a silicon diode we can measure .7v in a voltmeter.but why we can't use this voltage for using?

1921


What is electrical diversity factor in electrical installations?

1217


If I bring a basic electric meter from the States and hook it up in Costa Rica in a development that has only one transformer for the 50 homes, will it still be accurate regarding the usage of kilowatt hours?

1934


Why we use circular(Stepped) cross section in transformer core?

2257


what is the best method of grounding in 30 MW generator?

2033


How does "OUT OF STEP" relay ,for Synchronous motor protection, work?

4348


i want wipro vlsi placement pattern please send me

1780


What are the main faults of DC generators?

3000


what is the calculation method to design core and winding of a 200kva 3phase distribution transformer?

2399


For a 6.6kV Motor it is recommended to do megger test with 500 V d.c and not more than 5kV d.c but the Hi voltage withstand test should be performed by 12kV AC. Why the dc voltage test should be limited but AC voltage withstand test could be with such a high voltage?

2327