Can motor act as generator (OR) vice versa? explain how
does it do please post the answer technically

Answer Posted / karthik_elec

in self exciter dc motors we can use as an generator, but in ac machines, squirrel cage induction motor we cant use as an generator because rotor winding is already shorted, in slip ring induction motor we can use but we need exiter, but in this case we cant get proper voltage and frequency ,because the construction of rotor winding is like that, synchronous motor construction already same like a alternator.

Is This Answer Correct ?    8 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What the main causes of transient interruptions on Over-Head Distribution Lines?

1590


For small size, high frequency coils, the most common core material is- a. )Air b. )Ferrite c.) Powdered ion d.) Steel

2522


How to design the NGR Resistance

1620


What is UPS and How do you maintain the UPS Maintenance? Brief Description on UPS maintenance.

2136


why capacitance effect is predominant in underground cable transmission and inductance effect is predominant in over head line transmission?

3194






sir, iam a electrical engg graduate and i want to go in automation sector and for this i have decided to do industrial training for this,plz suggest me some good institute for the same in delhi,ncr. my degree percentage is 58%, can i get job after doing training, plz help....

1585


the site measured knee point voltage of protection class CTs should be greater than rated knee point voltage? what about meetering class CTs. Should it be below the rated knee point voltage?

1639


A 15 kw squirrel cage motor having a maximum efficiency of 90% on a continuous full load has temperature rise of 42 degrees celcius after 30 min and 52 degrees celcius after 1 hr under the above operation conditions. a) calculate its final steady state temperature rise on continuous load and the heating time constatnt. b) if the motor is operated on a short load for 9 min estimate its temperature rise. c) calculate the maximum overload that can be applied on a short, 9 min rating so that the temperature rise is the same as the final steady state temperature rise on continuous load.

703


why we are not giving the zone 1 trip command to the master trip relay

1084


what is the condition for YnD11

2084


what is the difference b/w ATS and HTS?

1711


How to calculate Temp from Resister from PT100 equation,

1208


What is the difference between DOL starter and star delta starter

580


with 3 phase board on a 63 amp rcd is it ok to have 6 electrical showers 2 on each phase and what problems could happen

1406


What is PEC??Applications........

1510