Three phase star connected PT transformer primary side one
phase fuse is blown what will be the output in secondary
side(Secondary side also three phase star connected)
Answer Posted / ved prakash
This is in order to compensate for phase shift due to Star/Delt or Delta/Star connections of primary and secondary windings. Becuase if the phase shift is not compensated, differential protection will operate.
Is This Answer Correct ? | 2 Yes | 6 No |
Post New Answer View All Answers
If VFD is On but no starting commond on it. so how many outpout voltages of VFD
i have been tasked with a design of protection, metering and control(PMC) relay panel extension to accommodate all PMC relays.There is an already existing panel where this one will be built.What are the design aspects for this kind of project? thank you.
Assuming that a dedicated neutral earthing transformer is provided for each GT generator, when the two generators are running in parallel, has consideration been given that the earth fault current from one generator stator winding be split between the two neutral earthing transformers? If so, what adverse impact will this have on the operation of the 59N and 27TN devices?
Why Stabilising Resistor used in REF circuit ?
what is mean by restructuring power system?
which are the criterias needed to select the kind of neutral earthing(solid earthing,resistance earthing,etc.) at various voltage levels in electrical distribution?
Dear sir, iam completed iti ncvt electrician 2000-2002 & diploma electrical eng completed 2008-2010 distance education in rvd university, still i got B licences only but my working company want C licences, how to i get c licencese pls reply me iam in critical situation thank you karthick 9841637803
given data are load current & power factor cable core size? plz any one update the calculation formula
Give some differences between open loop and closed loop control systems.
hai friends i have BSNL JTO exam on next month so if any body have model question paper or give preparation tips to my mail id kumar4486@yahoo.co.in this will helpfull for my future .plz & thank u by kumar
Dear sirs, pls check this 4-20ma to RS485 module datasheet,pls guve me some suggestions. http://www.szsunyuan.com/sy/pro_more.asp?Productid=539 Thanks. E-mail:yunianjiang99@gmail.com
what shall be no load voltage of 132/33 kV transformer ? is it 33 kv of 34.5 kV
What is the name of transformers oil filteration equipment?
we are small scale industry in production of rice & rice bran. Pls let me know how to take contract demand for our industry.. (for information we have total 600.hp)
there are cam operated switches - why we call cam operated , What is cam ?