Answer Posted / habib
Your question is not clear. Did you mean the scoop tube? If
yes, scoop tube is not the part of BFP. It is the part of
Hydraulic coupling. And not necesarilly all the BFP is
having hydraulic couplings. According to the position of
scoop tube oil quantity(flow rate) of the coupling is
maintained. The higher the oil flow, the higher the output
speed of the coupling and vice versa and same to the BFP.
According to the steam flow rate in the turbine feed water
flow rate should be matched. To get the variable flow rate,
variable speed is required for the BFP. And so far the
hydraulic coupling is the most efffective solution to serve
this purpose.
| Is This Answer Correct ? | 22 Yes | 0 No |
Post New Answer View All Answers
I m having skype interview with germany team what are the common questions asked?
Explain the hooke`s coupling.
Where do you work in engineering company?
Define earth lamp?
Why pert is preferred over cpm for evaluation of project ?
What are the causes of troubles in boiler during operations?
What do you understand by eutectic ?
Heavy fuel oil sulfur content and counter measures?
what is the three types of combustion-control system?
What are the different types of brakes?
Which pipe should I use SAW, ERW or seamless if I have the following constraints I have to transport methane gas Size is 8” Corrosive environment Sulphide is present Also tell the cost comparison
what is first law of Thermodynamics ? What is second law of Thermodynamics ?
What is the difference between Maintenance Order and Production Order. the point is i want to know the affection of Movement type 261 thru maintenance order and Production order. if i change any settings for Maintenance order it will affect to production order process also for 261 movement type ?
What is the full form of wcb in astm?
why coposite materials are sronger than solids