Why we are using air gap magnetic condutors

Answer Posted / vijendra joglekar

We are using airgap for decreasing and increasing Magnetic property and current value. I.e if you increase the airgap Magnetic property will be low hence it will increase the current value and the losses will be more.
Similarly if u decrease the airgap the reverse thing will happen. The airgap depends upon the type of equipment you are connected.

Is This Answer Correct ?    16 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

In cable sizing calculation (determining the max route length of cable) why we choose the shortest length between cable length of full load current Iflc & starting current Istart?

2776


What will be the effect if I use inverter as UPS mood?

1751


if the number of poles generated in stator and rotor side of an induction motor are different then what will happen and why?

1358


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

1507


what will be project cost for 100 kv transformer connection under oyt scheme.

2406






What is the formula to calculate a three phase alternator

1786


Why squirrel cage motor can only use with low starting loads ?

1557


What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side

974


How to calculate Air conditioning capacity for a telecom BTS shelter?

3043


pls someone send me sample question papers along with the key.thanks in advance

1885


The power factor of the fixed load is 0.8, now the p.f is varying from 0.8 to 0.5.

1572


i will applied in 1U-1W on 440 volt primary delta side. what is the result of magtic balance test

1378


in indoor type circuit breakers why only the corner breaker trips specially during cold season. What is the reason.

1440


You are of electrical field and you are going for software? Why

1849


from which subjects most of the technical que will b asked for hpcl(electrical).pls help me

1573