How conduct the hydro & pnumatic tests of Pressure vessels
as per ASME & as per EN Standerds.

Answer Posted / jitendra roul

As per ASME hydrostatic test pressure is 1.5 times of that
of Design Pressure and pneumatic test pressure is same as
design pressure.However pneumatic is highly risky, So
always preference should be given to hydro-static test
pressure.

While conducting hydrostatic testing care should be given
to vent the air trapped during water filling at the top
most point.

Is This Answer Correct ?    13 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the fuction of asstt. rigman drilling

4140


What are the causes of L.O. high temperature?

1760


What is the materials of cotter joints?

685


What are the causes of low compression in the main engine?

1383


i am preparing for motor vehicle assistant inespector please send me old questions papers.

1495






What is the use of flash chamber in a vapour compression refrigeration cycle to improve the cop of refrigeration cycle ?

683


What is meant by laminar flow ?

676


Explain working of Kaplan turbine?

707


What is an oil mist detector

1580


Is there any metal that does not contain iron?

730


What are the advantages and disadvantages of screw harmatic chiller respect to centrifugaal chiller machine?

2052


What pressure is highest L.O. Gravity Head or S.W. of the stern tube circulation

1694


How the F.W.C. system of diesel engine circulate?

1881


efficiency of diesel generator set:kwh x 3410 x 100/ fuel in ltrs x 0.87 x 2.2 x 19000. is it correct formula

2067


What is blading efficiency of steam turbines ?

885