what is the principle of switch gear? where its function ?
Answer Posted / aman rana
switchgear is a combination of ct,pt,circuit breaker & relays. it is used to break the load under normal & abnormal condition. in the switchgear ct will sense the fault current & relay calculate the type of fault & give comand to circuit breaker for trip the circuit .
Is This Answer Correct ? | 8 Yes | 3 No |
Post New Answer View All Answers
if there are six generators (3 gas CATT, one Jenbacher o1 MW each, and two nos Diesel 01 no 01 mw other 0.65mw EDGs ( say), 3 CAtt gas set have identical pole pitch,01mw EDG and Jenbacher gas Set have different pole pitch, how their power connection can be done to connect a common bus bar during installation. in short, how different pole pitched generators power connection can be done to connect a common busbar system through generators incomer ACBs.
Does magnetomonopoles exists? one maxwell equation strongly suggests no, but how about their existance in plasma?
how to calculate regulation constants for over head lines? and what are the regulation constant for raccoon conductor at different voltage level and different P.F?
Power factor =1.000 at factory in supply. However, PF = 0.8 at motor end. Current = 100 Amp, Voltage = 400 V. What is the power distribution loss? Can I reduce it by adding capacitor at the load feeder?
No load tap changing transformer working
A 230V dc shunt wound motor has an armature resistance of 0,15Ω.When operating on no load at 650 rev/min the armature current is 6A . The motor takes a full load current of 85A. Calculate the full load speed if the field flux is (i) maintained constant (ii)reduced by 0,03
At the starting of dc motor and syn.motor and induction motor high current flowing through the winding. Due to this the windings burnt out. To avoid this different types of starters are used. But incase of transformer what Will be used (At starting no emf is induced in the primary winding)?
What is reactive power and where it is used.
There are a trformer and an induction machine. Those two have the same supply. For which device the load current will be maximum? And why?
what is the maximim current drawn by 1 phase and three phase welding machine
Define bibo stability.
what is magnetizing current test in power transformer
We have received supplies of the ordered material. payments against the supplies also released. Where ST paid 4% against form C. Meanwhile it has been observed that 25% of material supplied was defective. Please suggest whether the issuance of C form from our side would be stopped till settlement of liabilities.
can anybody send me syllabus of rrb section engg (electrical). and also send previous question pepar...
which pump used in WTP explain the function of VFD how to dtermine capacitorbank of capacity one plant