how can we measure the level measurement with the help of
pressure gauge?

Answer Posted / anish kumaran.r

Using purge tube method you can measure the level by a PG and a air regulator. But it needs suppy air. Make a 'T' setup and connect gauge at one end ,supply air at one end and another end should be inserted in to the tank where the level to be measured. The gauge shows t level of the tank we shd convert into mmwc.
Regards,
R.Anish kumaran,
C&I Engineer,
Thermax ltd.

Is This Answer Correct ?    2 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why do we have earthing cable in branch cable and shield in the same cable?

2149


What care will you take in the installation of control valves,SCADA,DCS and FOC in Oil and Gas Project?

1649


hi friends,im an instrumentation and contol engg student,can u hlp me of suggsting barc written question paper,my id is roysuvaranjan@gmail.com, cel no.9563591747

1572


What is standard of DCS panel design?and what is step of DCS panel design?wiring and type of connector(screw or DB connector)

1718


I was working on calibrating turbidity transmitters endress+hauser at effluent polishing plant.We calibrated using NTU buffers.What happened is that when we immersed the sensor, everytime we raise and lower the sensor gradually, the reading will vary.my question is that is there any specifications on what is the required distance from the bottom of the container with buffer to the face of the sensor?Is it ok to install the sensor in a medium which has turbulence specially if bubbles are present?

1735






Describe a time when you anticipated potential problems and developed preventive measures.

2484


What is force balance principle?

703


Capacitance, resistance ( colour coding ), parallel & series circuits.

1739


I will attend an interview with GasGas company for a position of Instrument Technician ( Offshore )in next month can anyone tell me what questions they will ask. Thanks in advance.

1650


what is basic difference between motion balance and force balance in pneumatic instrument?

8955


NPN transistor, SCR, Zener diode, LED, Varactor diode, Vortex meter, RTD, Resistor, Crystal

1744


all types of liquid analyzer principle with drawing?

1538


Hi i am aneesh, done btech in applied electronics & instrumentatiin. And then i took mba in finance & marketing.After that i got placement in finance co and worked there for 3.5 yrs.Now i wanted to come back to engineering job.But without engg experience, i may not able to find an opening.i have done a course related to flow meters and ite calibrations. Kindly suggest where should i try to get a job?

1535


What is Cavitation in a control valve?

1559


Explain the difference between plc and cnc?

566