1.why ACB is not connected in HT side what Happens?
2.how much voltage maintained in ACB breaker?
3.OLTC is connected in primary side in case secondary side
connected what happened?

Answer Posted / karthikeyan

ACB there is a limit of current may pass through the contact machanism.High voltage side not possible to connect the ACB.
ACB max voltage can be maintained up to 415 volts that means it is purely applicable in LT side.
OLTC not possible to connect in secondary side because secondary side there is a continious load connecting that cause a huge problem may occur in sec side.

Is This Answer Correct ?    2 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Diagram on interconnectivity of 11kv transformer with RMU (i.e, one incoming and two outgoing or two incoming and one outgoing)

2221


how to calculate current and voltage in a same circuit?

1685


Explain the purpose of inductor in an electric circuit?

642


for 4 MVA , 33K.V/6.6K.V transformer. secondary side the connected load is 3000H.P. What is the rating of capacitor bank to be insttaled.

2153


why using transformer and thyristor switch in 3 phase apfc panel

2386






In between UPS out going changer over switch and ups raising main input, both side cable gland producing heat but the cable doesn't get heat,Why?

1729


HI....HOW CAN BE MESARED THE VALVE OF NEUTRAL GROUND RESISTOR WHIC IS LOCATED AT SWICHGEAR ON GENERATOR SIDE....

1614


What is the current carrying capacity of 35sq.mm flexible cable?

1038


why use phase displacement in transformer.and effect of phase displacement on transformer

2331


Hi Suppose we have a wye/wye transformer which is grounded at both sides,in this situation, do we have ay ground transformer? in other words, ground transformer can do any thing more (while we have nuetral wire in both sides)? As the last question, what about 3rd harmonic? we have two choices: first using wye/delta transformer + ground transformer and second using wye/wye earthed connection.in the former choice, we dont have 3rd harmoonic at the secondary side but what about Yn/yn conection? do we suffer from 3rd harmonic in the Yn/yn connection?

1533


how we provide neutral earth on synchronising panel as per electrical standards?

1598


CAN ANYBODY PLEASE TELL ME HOW TO DESIGN A SERIES REACTOR FOR LIMITING SHORT CIRCUIT FAULT CURRENT??

1454


where we use the SFU & FSU?

1986


distribution transformer de-rating formula on over limit iron losses  

1812


Explain Even and Odd signals?

1434