how to derive kg/cm2 to mmwc? complete derivation.

Answer Posted / gopalakrishnan

1 bar = 10000mmh2o
and 1 bar = 1000mmh2o is wrong

Is This Answer Correct ?    14 Yes 16 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the different between deflection type measurement and null type measurement in RTD?

1451


What are primary elements of measuring pressure?

762


what is function of SCADA , and how is it work, explain with difination

1831


TEMPERATURE VARIATION FOR FREQUENTLY.

1515


what is effect of specific gravity in differential level transmitter , explain formula related with this .

1225






Why even multiple power supplu r used in instrumentation system?

4157


how many pulses are required by a ac induction servo motor of 4 poles with 50 Hz frequency to rotate by 1 degree?

1678


what is difference between HOT permit and cold permit

1604


what is the advantage of submersible level transmitter compare to ultrasonic level transmitter?

1624


Define cryogenic?

718


Do you have reference list?

1421


What materials are used in thermo wells?

617


1.what is the effect of vapour presuure in orifice plate flow measurement 2.which is more effective 2 pressure sensors or one single differential pressure sensor in orifice plate measurement 3.how to design a v/i converter and i/v converter 4.how many type of thermocouple are there 5.how many leads are there in thermocouple measurement 6.how pressure sensors are connected in level measurement in differential pressure method 7.what is the output of capacitive pressure sensor (ac or dc),how its o/p is signal charactarized 8.what is the physical meaning of discharge coeeficient,why it is calculated,orifice plate what is its value,why it is less than 1,Q at upstream is equal to or not equal to Q at downstream of orifice plate why?what is vena contracta in orifice plate 9.why rotameter is called variable area flowmeter,it can measure flow even if area is not varying,why it is made tapered 10.design a 10 bit counter ,which counter you will prefer 11.how to remove self heating error in RTD 12.which is more sensitive pt100 or pt50 13.why thermocouple are connected in parallel 14.what is lead contact error in RTD,how to avoid 15.what is P,PI,PID,PD controller,why there is no ID controller 16.what is override,split range,sequential,ratio,feedforward,cascade controller 17.why we moved from SR to JK and then JK to master slave JK flipflop,give correct reason 18.how to measure level of a closed container which contains vapour and liquid,remember no vapour gas should be leaked,so ultrasonic and capacitive is not an option,design another method 19.how to design horse race counter including sensors and signal conditioning element 20.what is bevelling

1958


what is orfics working in main steam line. is it increase pressure, velocity of steam flow and dicrease steam flow rate. or any other

1674


How to work togather like sov,limit switch,proxy switch and booster in xv