can a control valve works without positioner?why need
tunning of c/v?
Answer Posted / goutam chatterjee
first of all we cant say any valve as a control valve with
out positioner... because we know that control valve is a
final control element.. we only say any valve as a control
valve when its acted as percentage operation as per process
requirement. with out positioner this is acted as a simple
on off valve... because percentage opening not possible with
out positioner... & we need to calibration the positioner
because cv alwys maintain the process in aspect of its final
contron ability.... i.e if process need to open the cv 25%
if the positioner not calibrated then it may be open 30 or
10 % for example... thats why we need to calibrate the
positioner.....
Is This Answer Correct ? | 13 Yes | 1 No |
Post New Answer View All Answers
what is the protection system in solar turbine compressor
Explain how thw analog to digital converter works with the circuit diagram
if in a level tx height is given, how u calculate the ranges of the tx?
Why we are using reverse action in displacer types level transmitters on some Vessels?
what is a good line as ic engineer as maintenance ,oc, project, calibration ,validation engineer?
Define the difference between a stable versus an unstable controlled system and some of the tools you might use to be able to detect when this is happening and assumptions used for control system application design that could contribute to instability
where uses EXe /EXd/Exo/Exn/Exp/Exq/EXia
Which Signal hart communicator work? If there any signal change when hart connect while transmitter in line ?
Dear Friends, we are planning to design Power distribution and Fiber optic in the same cabinet.Like Front side Fiber optic and Rear side Power distribution.Is it any possibility of problem occurs like interference etc? Your answer is highly appreciate.
Why do we have earthing cable in branch cable and shield in the same cable?
What is intrinsic safety mean.
What are different type of instrument cable
what is scale factor of proximitor & unit of the vibration.
why we r opening HOT BYPASS valve during startup of a compressor?
A DP transmitter is used to measure the level of an open tank. The drain line of the tank is connected to a control valve, and is configured as, if the level of the tank is 90% the valve should get open 10%. And if the tank level is 10%, the valve should get open 90%. Draw wiring diagram and explain how to configure DP transmitter and control valve using HART communicator. If the span error at output is 1%, what will be the %opening of the control valve at 60% level of the tank?