Why the transmision line are
11,33,63,132kv?
Answer Posted / nitin goyal
Its not form factor, if it was so then why there are 400KV
or 765 KV lines.
Answer to it is just a coincidence, It all started in 1881
when first hydroelectricity generator was set up in niagara
falls. That generator produced 110V and then onwards it all
started with that
So it is a mere coincidence that there are 11,33,66,132 KV lines
Is This Answer Correct ? | 4 Yes | 10 No |
Post New Answer View All Answers
1. A bomber drops a bomb from an aircraft flying at 2000 km/hr. at an altitude of 7km. The speed at which the bomb will strike the earth would be
What is core CT & it's function?
How many wall/floor flange will i use in bus duct system if we have in our design a 35th floor building.
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
please give me all the Alarm .Trip ,Safety Relays & Conditions of UPS Systems mail me on ashokbabunhce@gmail.com
at meter room 50 hrc switch installed,but there are not get earthing proper,so what happen?and 11kv transformer out put going in to hrc main 400a three nog each? so earthing is require for all switch? (some customer made earthing at there home.)
WHAT IS MEANT BY INSULATION CLEARANCE IN VACCUM?
What is resistance reading of earth copper rod with grid and without grid?
Differentiate between voltage and current feedback in amplifiers?
What happen in ups if phase reverse?
what will be project cost for 100 kv transformer connection under oyt scheme.
what is the use of permanent magnet generator in exciter
In the formula : Knee point voltage = Burden X alf / class, Please inform what is alf? regards Shashidhar M.R.
Difference between megger test equipment and contact resistance meter test instruments?
What is the difference between diode and a transistor in terms of the direction of current flow?