Q- In the process of checking AC through Phase Tester our
body is the part of circuit but we don't recevie Shock, Why ?
Answer Posted / kunal singh dabi
A mains tester works because the potential difference
between the live and Earth makes a very small
(imperceptible) current flow through the tester and our
body to Earth. This current is just enough to light the
lamp / Neon. When you stick it in the Neutral socket, the
potential difference (just a volt or two, usually) is not
enough to give sufficient current to light the neon.When
the tester light glows, it mean electrons flow like,from
live terminal > tester > body > floor & walls of building >
inside the earth>goes back to the generator, via earth or
neutral conductor (Please note that somewhere, Neutral and
Earth are connected together so we have, in effect, a huge
loop of circuit.)
Above description is for AC supply only ( path complete
thorough earth or nutral to generator neutral), however
please note the fhilosophy is not applicable for DC supply
where - V is in floting condition (not grounded or earthed)
so due to un completation of that circuit tester light will
not glow.
Is This Answer Correct ? | 6 Yes | 1 No |
Post New Answer View All Answers
hi friends,im an instrumentation and contol engg student,can u hlp me of suggsting barc written question paper,my id is roysuvaranjan@gmail.com, cel no.9563591747
TECHNICAL/ARTITUDE
Instrumentation Safe Guarding test. How to determine the interval time of the test. eg:Halfyearly,Every year,Every three years etc.
What are different types of cable?
Why upper weighing limit of electronics balance is 90% of the total weighing capacity?
How to Calibrate Vortex Flow transmitter in field
Can Any body tell me how to check Modbus Settings in ER300N L&T trivector meter?
please send me the inteview questions in IOCL
hye SAM acn u send your e mail id, so that i can solve my query through e mail?
In my company plc based winders are operated. one day there was a data transmission failure alarm shown on pc. as per sir instruction we have reset master plc but winders were not triped and alarm gone. so what master plc do?
Regarding , there is an air cooler which control the fans(50% of AV FANS) by temperature in outlet , and the louver of Air cooler is controlled by HIC from control system , So if on Air cooler we will consider 2 individual I/P converter or positioner?
selection criteria of control valve? and selection criteria of actuator explain in brief?
Draw bode plot of any transfer function. Why is plotting bode necessary?
What are different types of control valves?
What is PDS and PDMS ?