what is idmt relay

Answer Posted / karun

Inverse Definite Minimum Time Lag = IDMT relay

It's a electromagnetic type rotating disk relay.

Tripping time of relay decreases with increasing fault current.


Read more:
http://wiki.answers.com/Q/What_is_idmt_relay#ixzz18ZiYIQIj

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How will be the single line diagram of series trip HT breaker? how it works?

2097


what are the advantage and dis-advantage of 3 phase 4 wire energy meter?

1466


Give some differences between open loop and closed loop control systems.

673


how invertor convert the dc into ac give brif detail

1539


What is transient response?

670






What are the internal and external faults?

622


what is the responsibility of C license holder in industry?

8548


why swinburnes test cannot be performed on series machines?explain

1840


Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1.  H1-H2 = H2-H3 H3-H1 2.  H2-H3 = H3-H1 H1-H2 3.  H3-H1 = H1-H2 H2-H3 For the LV side also: 4.  X1-X0 = X2-X0 X3-X0 5.  X2-X0 = X3-X0 X1-X0 6.  X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0  H2-H0  H3-H0    X0-X1  X0-X2  X0-X3 128.0  119.9  7.2      29.2   13.3   15.8 70.7   128.4  59.2     23.4   22.0   3.6 7.2    120.1  128.1    13.4   29.3   15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?

1370


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

1565


How to know the following data of synchronous generator 1. D-Axis Unsaturated Reactance 2. D-Axis Unsaturated Transient Reactance 3. D-Axis Unsaturated Sub - Transient Reactance

1479


In the N-series schneider reclosers. What is the difference between current during fault time and current at tripping? This appears in the Event log in an event of a trip out.

1342


Explain what is electric traction?

662


sir vizag steel ka junior trainee ka paper kitne number ka ayega

1773


How is the percentage impedence of a transformer fixed at design stage???

1506