why should be the frequency is 50 hz only why not others
like 45, 95 56 or anything ,
why should we maintain the frequency constant
if so why it is only 50
Answer Posted / kalidhas
50 Hz frequency is the indian standard maintained in power
sysytem so that all electrical eqquipments are designed in
at this Frequency.Otherwise not other reasons..
| Is This Answer Correct ? | 2 Yes | 1 No |
Post New Answer View All Answers
# 4 hi friends i m from electrical branch and seeking for tech. + apti. both papers of hpcl plz get it available as soon as possible my email id is sumit_lig189@yahoo.co.in
Electrical 'C' license full abbreviation , and full form
How to design the NGR Resistance
Match the following a)(X'+Y') b)X'Y' C)XY 1)NAND 2)NOR 3)Carry
is it necessary to earth the rmu before cutting off the transformer winding?if yes why?
Yazaki india pvt ltd interview questions qurey related
Hi Friend I am used multimeter to measure the voltage between R Phase(SS1) to R Phase(SS2). In SS1 is connected with UPS loads. But I am getting voltage between these 2 R Phases. Please give some idea friend
WHAT DO YOU MEAN THE DIFFERENT TYPE OF CURVES OF RELAY LIKE STANDARD INVERSE, VARY INVERSE, NORMAL INVERSE, LONG INVERSE ETC....
A 50Hz,4-pole,3-phase,star-connected synchronous motor has a synchronous reactance of 12ohmsper phase and negligible armature resistances.the excitation is such as to give an open-circuit voltage of 13.2kilovolt.the motor is connected to 115kilovolt, 50hertz supplying. what maximum load can be the motor torque,line current and power factor?
difference between main metering kiosk and check metering kiosk
why fractional pitch winding generally used in alternators?
What is q factor?
Which are resistive loads & which one are inductive loads : Refrigerator, Split air conditioner, ceiling fans, well pump, fluoresecent bulbs, T.V, CRT Monitors, Adsl Routers, C.P.U, Printers, Deep Freezers, Speakers, DVD Players, Microwave oven etc. ? Output Power for these Appliances Would be same like this : P = V * A * P.F Or would be changed ? thanks
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
what is the most permissible winding temp when we conducting a generator load test?(condition no load)