In tranformer winding Connection Like Dyn1 ,so LV lags Hv
by 30 deg and Dyn11 LV lead HV by 30,so how do this lagging
and leading afffect the transformer??

Answer Posted / k.prakashchandra

it is inevitable if primary and secondary are connected in
different groups except for Dd6 and Yy6 and does not affect
the tr

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

1.what is mean by 8/20 micro sec waveshape

1794


WHAT IS IEC? & WHAT IS BENEFIT TO PRODUCT FROM IEC?

1677


What is the Nyquist criterion regarding control systems?

660


What are different types of control systems?

741


How can claculate to attain the desired PF in the line ( HOW Much KVAR is required ) Pls Give the formula? Equate Petrochemical 0 1 how to calculate sizing of NGTR (Transformer rating,Loading resistor value and Current rating of resistor) and what is the X/R ratio. Details : 11kV,Capacitance 1.73532 micro farads,40kA for 1sec. 0 1 What will happened. if we feed 3phase supplay to the stater with out insert the rotor. How much current will flow through the stater winnding? Equate Petrochemical 0 1 What is required of exietation to the alternater. 0 1 why star point of HT motor not earthed? Equate Petrochemical 0 1 Why we are getting low voltage in star connection? Equate Petrochemical 0 2 What's ND relay & it's functions? Equate Petrochemical 0 2 How instantanious short circuit current is calculated? its formula? Equate Petrochemical 0 2 What is servo Motor? What's the advantages of this motor over Induction motor? Equate Petrochemical 0 2 What is core CT & it's function? Equate Petrochemical 0 3 what is meant by star/delta voltages as 440/220 in a 3 phase induction motor, and why it should be connected on STAR IN 3 PHASE SUPPLY L & T 0 4 What is required of exietation to the alternater. KNB 1 23 what is the design voltage for 6.6KV 2000 KVAR HT capacitor? Consultancy 0 3 Pls explain about vfd control?Where it is used, Give some example? siemens 1 22 Please explain me abt PQ diagaram in the power sector. 0 9

1610






Is neutral transformer can be called as control transformer?

1526


A 3-PHASE TRANSFORMER IS USED TO STEP-DOWN THE VOLTAGE OF A 3-PHASE, 11KV FEEDER LINE. PER-PHASE TURNS RATIO IS 12.FOR A PRIMARY LINE CURRENT OF 20A, CALCULATE THE SECOUNDRY LINE VOLTAGE, LINE CURRENT AND OUTPUT KVA FOR FOLLOWING.A)STAR- DELTA.B)DELTA-DELTA.

2450


what is the usage of microcontroller in the panel board?

1552


Hi, This is Laila. I am selected for syndicate bank interview. Could you please share your views and the questions asked if you have faced the interview My email id is laila_honey09@yahoo.com Please send as fast as u can.Thank You Thanks... Laila.

1635


What are the parameters of water ( Water quality )to be monitored in Centralised HVAC ( water cooler chillers )

1635


What are the basic elements used for modeling mechanical rotational system?

618


how braking & making capacity of circuit breaker are calculated?

1849


Logic using 1 kV or 1,1 kV grade in house wiring Low voltage cable. Explain/suggest? some use 1kV and some prefer 1.1kV grade insulation low voltage cable why??

1218


draw the full wave and half wave circuit of 3 phase system and inverter circuit used in upsĀ 

1920


What is the difference between the transmission line and distribution line?

666