What is principal to reduce earth leakage current with
isolation transformer? When isolation transformer is
installed in input stage of system, earth leakage current
is reduced. the reason is why the leakage current of 2nd
stage of isolation transformer does not affect the 1st
stage's leakage current. I would like to know the reason.
As you know, earth leakage current is a kind of AC. So, How
to reduce earth leakage current in case that isolation
transformer is used?
Answer Posted / k.prakashchandra
If the neutral of secondary is not earthed ,the phases of
secondary lose the reference to earth ,but slightly for
capacitive coupling. After the second stage ,the earth is
almost completely isolated.
Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
Where can I get Iidian straderd specifications for electrical items or works in web? please help me.
At the starting of dc motor and syn.motor and induction motor high current flowing through the winding. Due to this the windings burnt out. To avoid this different types of starters are used. But incase of transformer what Will be used (At starting no emf is induced in the primary winding)?
How does a transformer contribute towards the widespread popularity of ac system over dc?
Please send 110 kv sb station full single line drawing(sld)
Merits & Demarits of Oil circuit & Air circuit breakers ?
c++ write a program to use a fuction call "max"which accepts an intger arrey of size5.as an arrument and return the larger and smallest of the arrey to main without changing. the original changing of the original position of the element of the arrey.
Help need in transformer !? Hello Friends The parameters of 2300/230 v 50hz t/f is R1=0.286 ohm R`2=0.319 ohm Rc=240 ohm X1=0.73 ohm X`2=0.73 ohm Xm=49.2 ohm Secondary Load impedance ZL=0.387+J0.29 solve the exact equivalent circuit with normal voltage across primery.. I know every thing but i cant find CURRENT I1=? and I`2=? Please help me give solution or only Formula please please...
how much allowable resistance that can be difference in motor all coils?
we are going to install a solar PV site and how can we calculate PV Solar Panel Efficiency, can anybody tell me complete method for its calculation.
How do we arrive at selecting reactive capacitance value as 30% of h.p rating of motor?
How shall i select the value of capacitor or inductor in a system?
What do you mean by pull of electromagnet?
what are the protecyion of transformer & generators
When is lag lead compensator is required?
How we can defined theecopper cable size if we know the aluminium cable size?