what is the meaning and difference between ELECTRICAL
DRAWOUT and MANUAL DRAWOUT?
Answer Posted / ranjana
manual draw out is the De-assembled procedure of
trolleys(VCBs) FROM PANEL.
A circuit breaker racking mechanism has a toroidal spring
connected between an inner and outer racking shaft. The
inner shaft is connected to the cubicle within which the
circuit breaker truck is moved while the outer shaft is
connected to the manual racking mechanism. The spring serves
as a direct mechanical force transmitting connection between
the inner and outer racking shafts when the breaker which
enters the cubicle is moved to the test position. After the
breaker reaches the test position, the inner racking shaft
is latched so that continued racking toward the connected
position charges the spring connection between the two
racking shaft members. The latch may be remotely defeated to
release the spring, thereby to complete the racking of the
breaker to its connected position under the influence of the
charged spring with operating personnel in a remote position.
Is This Answer Correct ? | 2 Yes | 4 No |
Post New Answer View All Answers
Can we check ELCB constantly from R1 to R8 phase in 1 no DB?
what is the voltage rating of chiller unit sensors
hi frnds can any one help me ? plz send me placement paper of IOCL of Electrical streem .... plz send ....its urgent....
what rectifiers is and what are the types of rectifiers?
the grid connection required for a 50 MegaWatt fotovoltaic powerplant is higher or lower than 35kv (high or medium tension)?
how to handle 2500 kva transformar
In an ACB shunt trip coil and undervoltage coil operated normally( breaker open and charged). But closing coil not operating untill manually discharge and recharging. Any help.
Why we use duplex coil and hook switch in telephone system?
how to carry out Magnetizing Current Test on Distribution transformer and what purpose we are doing this test. why transformer rating in always in KVA ? what ispositive, negative, zero sequence impedence? How ElCB tripping if Neutral touch with ground Why AC & DC capacitor are use in UPS ? why motor rating in KW? how to syncronize two dg sets
What is the type of feedback used in an op- amp schmitt trigger?
I'm generating a pulse of 3V with frequency 80Hz (12.5ms time period) and pulse duration 0.125ms and feeding it to a transformer since i want the pulse to get amplified around 60V. At the output amplification s happening but the pulse is changed to a spike, can you tell me what could be the reason? (an ordinary transformer 220V-12V stepdown transformer is reverse connected ie. now it is 12V-220V stepup and voltage amplification happens)
What is electrical cable termination
1 hp is equal to how much watt?
How can eliminate noise problem inside temperature controller temp. variation due to contactor chattering problem.
What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works?