what is the meaning and difference between ELECTRICAL
DRAWOUT and MANUAL DRAWOUT?

Answer Posted / ranjana

manual draw out is the De-assembled procedure of
trolleys(VCBs) FROM PANEL.
A circuit breaker racking mechanism has a toroidal spring
connected between an inner and outer racking shaft. The
inner shaft is connected to the cubicle within which the
circuit breaker truck is moved while the outer shaft is
connected to the manual racking mechanism. The spring serves
as a direct mechanical force transmitting connection between
the inner and outer racking shafts when the breaker which
enters the cubicle is moved to the test position. After the
breaker reaches the test position, the inner racking shaft
is latched so that continued racking toward the connected
position charges the spring connection between the two
racking shaft members. The latch may be remotely defeated to
release the spring, thereby to complete the racking of the
breaker to its connected position under the influence of the
charged spring with operating personnel in a remote position.

Is This Answer Correct ?    2 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Can we check ELCB constantly from R1 to R8 phase in 1 no DB?

1222


what is the voltage rating of chiller unit sensors

2289


hi frnds can any one help me ? plz send me placement paper of IOCL of Electrical streem .... plz send ....its urgent....

1289


what rectifiers is and what are the types of rectifiers?

625


the grid connection required for a 50 MegaWatt fotovoltaic powerplant is higher or lower than 35kv (high or medium tension)?

1431






how to handle 2500 kva transformar

1128


In an ACB shunt trip coil and undervoltage coil operated normally( breaker open and charged). But closing coil not operating untill manually discharge and recharging. Any help.

1277


Why we use duplex coil and hook switch in telephone system?

4576


how to carry out Magnetizing Current Test on Distribution transformer and what purpose we are doing this test. why transformer rating in always in KVA ? what ispositive, negative, zero sequence impedence? How ElCB tripping if Neutral touch with ground Why AC & DC capacitor are use in UPS ? why motor rating in KW? how to syncronize two dg sets

1708


What is the type of feedback used in an op- amp schmitt trigger?

636


I'm generating a pulse of 3V with frequency 80Hz (12.5ms time period) and pulse duration 0.125ms and feeding it to a transformer since i want the pulse to get amplified around 60V. At the output amplification s happening but the pulse is changed to a spike, can you tell me what could be the reason? (an ordinary transformer 220V-12V stepdown transformer is reverse connected ie. now it is 12V-220V stepup and voltage amplification happens)

1446


What is electrical cable termination

2212


1 hp is equal to how much watt?

711


How can eliminate noise problem inside temperature controller temp. variation due to contactor chattering problem.

1181


What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works?

1531