How does one convert an AC motor into a generator?
Answer Posted / sidda raghavendra
* For an induction machine:
at the time of starting if we can set the speed of the
machine is just less than its synchronous speed it works as
induction motor as we must give electrical power as input
at the time of starting if we can set the speed of the
machine is just higher than its synchronous speed it works
as induction Genearator as we must give Mechanical
(steam,hydral or diesel and so on) power as input
*For synchonous machine:
Its all depend on only the input of the machine
Is This Answer Correct ? | 7 Yes | 0 No |
Post New Answer View All Answers
WHY TERTIARY OF POWER TRANSFORMERS IS LOADED WITH EQUIPMENTS LIKE CT,PT,ISOLATOR AND CB
Compare salient pole and cylindrical rotor machines.
How to perform a DC resistance test In Alternator and their proceduces?
How can a equal potential zone be carried out in conductors?
how the testing of protection CT Testing done through Primary injection kit please describe in detail procedure...
which motor have relatively high power factor and what is reason for have high pf? 1.capacitor run motor 2.shaded pole motor 3.capacitor start motor 4.split phase motor
how can check the resistance of battery contact?
do anyone out there know where to find a compleete list on acronyms/abbreviations used in offshore electric engineering. MCB - Micro Circuit Breaker, MCCB-Mouldes Case Circuit Breaker, ELCB-Earth Lekage Circuit Breaker, ELMCB- etc.....
What is the typical enclosure type used for Indoor switchgear / Outdoor switchgear Units? - In Onshore / offshore Units?
Explain cmrr?
what is the grounding Calculation formula? spouse i want to provide grounding to 3phase 18kw motor or i want to provide ground to 3phase 10kva dry type transformere or you give me any exemple...... Thanks.
What is the basis for framing the rules of block diagram reduction technique?
This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.
1)we have 1000 cfm Blower,Dia-1Mtr,Velocity of air 94 m/s 2)We have Natural Air velocity 94m/s 3If i Put Wind Mill in natural air ,speed is 94m/s Then it will generate Assume 100kw 4)If i put same wind mill across the Blower,air speed is same 94m/s now the Question is Will it generate 100 kw?
i have attended the interview on 4th June,08 at Kolkata in IOCL, can anybody tell me what is its result