what happens when we give ac supply to the dc motor?and why?

Answer Posted / rakesh kumar

It all depends upon whether the motor is a series motor or
shunt , if the motor is series then it would be running but
quite unsatisfactorily with increased sparking during
commutation and heating. however a shunt motor wont run
because of the high inductance of its field windings ( due
to greater no. of turns ) it will oppose the change in the
magnitude and direction of current which is th case with
ac .

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Where can I get Iidian straderd specifications for electrical items or works in web? please help me.

1592


RATING OF LIGHTENING ARRESTER FOR 11 KV LINE IS 9 KV is ok ,but haw to calculate the KA rating?

1541


Why we use mho Relay in long transmission line?

959


what are your career plans upon completion of the programme and the relevance of recity generation to your professional development?

1762


It is desired to flood light the front of a building 42 meters wide and 16 meters hig.Projectors of 30 degree beam spread and 1000 watt lamps giving 20 lumen/watt are availabl.If the desired level of illumination is 75 lumen/m and show a suitable scheme.Assume the cofficient of utilization, deprecitation factor and waste light factor are 0.4, 13 and 1.2 respectively.

2980






Determine the BTU size of an aircon for 20 sq metre room

1457


How does the slip regulator works as a startor

1505


how oil in the MOCB was reduced compared with OCB? what are the features of the MOCB?

2351


while doing high potential for 11KV 3 core cable how much leakage current will obtain?, what will be acceptance value?

2431


DRAW ACIRCUIT DIAGRAM OF 100 KVA 415V/55-0-55V DELTA TO STAR TRANSFORMER

1617


can anyone explain the star-delta motor control wiring ,which wire go where and how they operate?

957


Did RMU have ct and pt ?

953


How can eliminate noise problem inside temperature controller temp. variation due to contactor chattering problem.

1192


we have two generators different capacity on 15 MW and other 6MW at 11 KV , 15 MW gen. bus short level current 40KA,and 6MW short level current 25KA,, length of cable 100MTR between 6 MW from 15MW gen. for bus coupling . kindly tell any one can we use both NGR OR one NGR from any GEN. BOTH NGR has diff. rating. Tariq pakistan

1230


in control scheme dc logic wiring commonly using negative loop,what is the reason?if we use positive looping what will happen?

1864