Difference Between Isolator and Mcb
Answer Posted / chandu
isolator is a operating manual system.
mcb(miniature circuit breaker)is operates automatically
| Is This Answer Correct ? | 15 Yes | 4 No |
Post New Answer View All Answers
If we connect a motor and generator together (I mean that the generator gives the motor electricity and the motor gives the generator movement) regardless the losses. Will the generator still generate and the motor still move?
What are steps to be taken while designing of DYN11 distribution transformer to achieve magnetising balance?
what a function diesel generetaor turbo charger & turbo charger is more heated explain reason ?
Why line VTG = √3 phase VTG in star? How?
how much GROUND & NEUTRAL VOLT maintain in data center.
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
what is Insulation monitoring device. where it is used? (in switchgear room or control panel or in field equipment)
What is Bolted fault?
how to check three phase motor torque value?
advantage of motor design on higher power factor . normally motors are designed for .8 power factor. what is advantage of designing at .88 power factor
we have require a Motor (1500kW, 6.6kV, 50Hz) which shall operate at 1500rpm during 30min and after it shall run on 500rpm during 15min. The same cycle shall be repetitive during the whole working days. Which method is best and economic to achieve such type of task. VFD, VVFD, Pole changing motor etc.
is that a problem if i connect a single phase load to a secondry delta connected transformer but i get a neutral from other transformer i the system?
What was your role in the silicon evaluation/product ramp? What tools did you use?
what is effect of leading power facter on the system and billing
how hydrogen cooled alternator undergo maintanence ? that is hydrogen when come in contact with air can result into explosions .