What is mean by PID controller? And what is its Long form?
Answer Posted / santanu sen
PID controller is also known as proportional integral derivative controller. The two main types of operation integral and derivative controller are used. The integral controller is used to minimize the steady state error of the response characteristics, it is the same as adding a pole to the transfer function of the control system. The purpose of the derivative controller is to fasten up the transient response, as the peak value is obtained earlier than the normal response, just as adding a zero to the transfer function of the control system. The proportional controller can be realized for two purposes:-
1. The derivative controller cannot be realized alone so therefore there must be a proportional controller for the same.
2. The proportional controller is also used to adjust the gain of the control system within the limits of the s- plane, otherwise may lead to instability.
| Is This Answer Correct ? | 4 Yes | 1 No |
Post New Answer View All Answers
Is it required to lay 2 runs of GI wires along with armoured cables from one power DB Machines of higher rating?
What is the formulae of Megger value for a A.C.Motor
What happen to generator if i have unbalanced load?
what is stper motor
which network topology offers the greatest level of tolerance?
How to select the proper VSD to operate high inertial load
how the synchronizing is obtained at bus couplers in grid substation? (because there we cannot change the frequency in one of transmission lines like in generator synchronization)
Ceiling Fan and Storage type water heater. Discuss
How to check the cable fault / hv test of transformer cable.
tell me about eletrical contractor
how to select size of hardware for linking aluminium busbar is it depend on area of busbar or current flowing through bus bar
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
1hp= how much rpm
TRANSFORMERS WITH DC SUPPLY
what is the criterion for selecting vector group of Transformers ? i mean how to decide vector group of Generator transformer, substation trasformer and transformer at consumer end