why v use only sodium bulb or orange color lights on
streets, y nt CLF OR TUBE LIGHTS
Answer Posted / nithi
People look more good (too fair)in sodium lamp(yellow
colour light).that's why it is used in the street.
just for fun.
I think,the lumens per watt is higher in sodium lamp.
(i.e. luminous efficiency of sodium vapour lamp may be
high.)
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
What are your personal skills and abilities for such a Master Course and your possible preparation to undertake this course?
plz send me HPCL apptitude paper.. maulik_elect@yahoo.co.in
errection check list for transformer maintenance
What is signal flow graph?
should %impedance be high or low in a power transformer? if so why?
1- XC and the RC time constant are both measures of the reaction of C to a change in ____? 2-The power factor is a numerical ratio with a value between 0 and 1 equal to the ______________ of the phase angle. 3-When V and I are out of phase because of reactance, the product of V times I is called ______________ power 4-For _____________ inductors, the branch currents can be added algebraically. 5- The ______________ power in watts can be calculated as I^2R 6-Calculate XL with L = 30mH and f = 1kHz ( I have Xl=2piFL 2*3.141592653*1kHz*30mH =188 ohms Please check) 7-A parallel RL circuit has the values, R = 5kohms, XL = 5kohms. A voltage source of Vt = 10Vrms is connected in parallel to R and L. Determine the total current, It delivered by the voltage source Vt. 8-A series RC circuit has R = 1Mohm and C = 1microF. How long would it take for the capacitor to fully discharge if it is initially fully charged? 9-A circuit has real power = 300W and an apparent power of 500VA. Determine the power factor and phase angle. 10-The time constant for an LR series circuit is T = 0.1s and R = 10ohms. Calculate the inductance L.
Why field rheostat is kept in minimum position while armature rheostat at maximum position?
How much ph is maintained of water resistance starter for slipring induction motor ?
What is the effect on in Zone and out zone fault if Phase side CT is Vk/2<30 mA and Neutral side is CT is Vk/4<30 mA for Transformer REF protection
aternator every parts and its working
Difference between On Line capacitor and Station Type capacitor.
how to select the isolation tranformer for siemens 802dsl cnotroller
What are the main faults of DC generators?
Give me the calculation steps to design an electromagnet to be work in 230V 50 Hz AC Supply. Also give force that is created by that electromagnet when it gets energized.
how to calculation increase capacitor,increase power factor for three phase.