tell how to calibrate a magnetic flow tx, vortex flow tx,dp
flow tx,nozzle flow tx and venturi flow tx?
Answer Posted / kiran kumar
Generally to calibrate any SMART flow transmitters, we need
to give direct ranges and fluid specifications through HART
Communicator. To check whether it is giving correct output,
we need to cross check the output of flow meter pipe should
be kept in a measured tank for a specified time and compare
the same with flow meter reading.
Is This Answer Correct ? | 2 Yes | 9 No |
Post New Answer View All Answers
what is effect of specific gravity in differential level transmitter , explain formula related with this .
HI friends.I am Surya a BTech in Electronics and Instrumentation Engineering.I am going to appear Relince Industries Ltd all India writen test very soon. so plz help me by sendind the probable questions about my subject.My mail ID is surya.barik@gmail.com.
we are using centum vp as monitoring with Dell precision work station T3600 but some times PC(s) are restarted automatically . how we can solve this problem? thanks
Can anyone convert a 5/2 way or 3/2 way valve into an ISO valve?
Calculate the maximum pressure drop that can be allowed to occur across a control valve, so that we can prevent cavitation / flashing from occurring. Use the following formula: Δ P allow = Km (P1 – PvapourA) where, Δ P allow - the maximum allowable differential pressure for sizing purposes, or terminal pressure drop; Km- the valve recovery coefficient from the manufacturer’s catalogue; P1 - absolute inlet fluid pressure; PvapourA - absolute fluid vapour pressure at the inlet temperature; Use Atmospheric pressure = 101.3 kPa, P1 = 1200 kPa(g), PvapourA = 4 kPa, KM = 0.72
Programmable Logic control.
Why we are using DPT(Differential Pressure Transmitter) in separator instead of level trasmitter?
How to Calibrate Flammable gas detector in field
How is work 5/2 sov?
how many types of viberation transmitter and how to calibrate and where use of vibration transmitter
Is it ok, to use non-contact type Radar type LT, on a tank that is half circular from the bottom side? If yes the, isn't the waves gonna bent in other directions?
How to calibrate level transmitter with use of HART?
PLEASE PROVIDE SAMPLES OF CHEVRON SKILL TESTS
I m appointed as an automation trainee engineer in small firm in that I am only the one , my company give me a project on s7-200 as i m beginner I don't know how to program so please send me the helpful site so that I complete my project before deadline....please help me out in this critical situation.
I was working on calibrating turbidity transmitters endress+hauser at effluent polishing plant.We calibrated using NTU buffers.What happened is that when we immersed the sensor, everytime we raise and lower the sensor gradually, the reading will vary.my question is that is there any specifications on what is the required distance from the bottom of the container with buffer to the face of the sensor?Is it ok to install the sensor in a medium which has turbulence specially if bubbles are present?