Answer Posted / joy
simplest way is apply a certain volume of smoke in a room
where the detector is placed that would be enough to trigger
the SD to send an alarm signal to its control panel that is
if this is not just the battery operated one.
Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
what is the profesional board for electrical engineer what is thepast and during construction for electrical engineering
at work we have a 3 phase motor but on testing one phase isnt getting a reading. it runs 24 hours a day all week. stops and starts well no noise or heating. the phase isnt down to earth.is it just a bad meter reading or not? phases one and three came up with a resistance reading of 0.4 but phase 2 couldnt get anything shows up as open circuit.
why transformer ratings in kva? & DG ratings in kva? & Motor ratings in kw/HP?
What is mason's gain formula?
we have require a Motor (1500kW, 6.6kV, 50Hz) which shall operate at 1500rpm during 30min and after it shall run on 500rpm during 15min. The same cycle shall be repetitive during the whole working days. Which method is best and economic to achieve such type of task. VFD, VVFD, Pole changing motor etc.
Why we use auxillary relay ? what is function of differential relay, directional o/c relay?
What would be the size of wire used for 2 Ton of window A.C?
Why should be the frequency 50 hz 60hz only why not others like 45, 95 56 or anything , why should we maintain the frequency constant if so why it is only 50 hz 60hz?
Circuit diagram of tube light without starter using electrical choke
what would u consider to be the basic purchase order information you would need to proceed with a cable inspection assignment?
How much costly in percentage wise is sandwich busduct costly than air insulated busduct of any rating?
A 100 kVA , 400 v/250 kv testing transformer has 8% leakage reactance and resistance on 100 KVA base . A cable has to be tested at 500 kv using the above transformer as a resonant transformer at 50 hz . if the charging current of the cable at 500 kv is 0.4 A find the series inductance required . Assume 2% resistance for the inductor to be used and the connecting leads . Neglect dielectric loss of hte cable . what will be the input voltage to the transformer ?
how to calculate cooling requirement of datacentre from electrical load?
If a air condition consume 2.50 to 3.00 amp then how much it will consume in watts if it is running 10 hours out of 24 hours????
What do you mean by transformation ratio of instrument transformer?