Bhel supervision exam question:
If 2 generators are working in a network. And if suddenly the
field of anyone generator weakens. What will happen in the network?
1. The generator will run as motor
2. The generator will run as motor in reverse direction
3. The generator will take lighter load
4. The generator will take more load

Answer Posted / bharat3832

1.The generator will run as a motor

Is This Answer Correct ?    8 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

can I improve the furnace power factor (10 mva transformer) by adding a capacitor bank before the transformer.Does system power factor vary a lot with the furnace PF?

1558


why are u join ntpc

1725


What is the suitable transmission voltage?

670


my UPS suddenly goes off and all panel light also blow off.This happens even main electric supply is not interrupted.After some time it automatically starts functioning normally.Batteries are new.

1561


What kind of preventive maintenance are there for transformer?

1783






Hi.. I am a BE GRaduate in E&E. I have 8.5 Experience in Tendering & Estimation field. I have done SAP SD course few years back. But due to some reason i failed to get job in that field and continued my own field. Now I am thinking of changing into SAP seriously. How should i go ahead???

1471


technically, what is the reason behind starting the motor star the delta connection .. and what other ways to do this rather than using " star-delta transformer"

1544


i am electrical and elctronics engg passed out in 2009 want to attend for reliance placements.plz send me apttitude ,technical and hr question answers to my mail plz. my mail id-kat.bindas@gmail.com

1553


How to calculate Temp from Resister from PT100 equation,

1204


What is knee point voltage?

674


Why compensation is necessary in feedback control system?

773


What does the kvar means?

659


In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes

354


How to calculate Voltage regulation of 22 KV Over head Line.

1191


we have two motors 1250kW,6.6kV to be coupled on the same shaft ,so please provide assistance for their synchronisation.

1633