what is the accaptable voltage between neutral to earth
& How to reduse the resistance of earth in chemical earthing
Answer Posted / tejswita tawade
it is upto 5v.
| Is This Answer Correct ? | 1 Yes | 2 No |
Post New Answer View All Answers
How does cost of generation from hydropower plant compare with other sources of electricity?
WHAT IS SUBSTATION & ACCORDING TO VOLTAGE HT,EHT SUBSTATION EXPLAIN IT
what is the difference between droop mode and ischnorous mode in thermal powerplant?
What is steady state response?
What is a parabolic signal?
i have to install a HT panel, what components, I have to use in this and what will the diagram of that diagram,please tell me each and everything.
IF I KNOW THE AREA OF CROSS SECTION OFTHE WIRE , WATTAGE OF THE LOAD ,VOLTAGE SUPPLY WHAT IM GIVING TO THE LOAD AND ALSO POWER FACTOR OF LOAD ....... SO GIVE ME FOR WHAT AMOUNT OF CURRENT I SHOULD USE WHICH TYPE OF CABLE?
Dear all, i completed M.E(Power Electronics & Drives) 2011 passed out having 78% so i need job in core side but i don't know how can i receive the calls from electrical companies and i uploaded my CV in naukri, times jobs etc.. In that iam not recieved any mails from good companies so give me best procedure plzzzzzzzzzzzzzzzzzzzzzzzz..... Thanks, K.Linga Reddy Email-id:-lingareddykmthm@gmail.com Ph no:-08015402078
when measure the core loss of three phase distribution transformer or three phase reactor loss, one phase shown negative watt loss. why??
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
Can anyone tell the proper diagram of star delta starter????
how oil in the MOCB was reduced compared with OCB? what are the features of the MOCB?
Why a tesa lamp is glow between two phase?
how you configure motorvision relay (L&T make)from DCS
Yazaki india pvt ltd interview questions qurey related