Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why Power generation in India is at 50Hz while in America
its 60Hz so is there any advantage/Disadvantage of this ??

Answer Posted / shah alam

we all know that the power generation in India is at 220v at frequency 50hz but in America it is 110v at frequency 60hz,the main reason behind this is that the impedance of inductor increases with frequency and that of capacitor decreases.if we find over all impedance of the combination of inductor,capacitor and resister we can see that the current supply would increase with a little decrease of frequency.the formula for current calculation is given as..
i= v/(r^2+(wL-1/wC)^2).
where,
w=2*pi*f.

Is This Answer Correct ?    7 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

if an insulated power and control cables of a running gas diesel gensets laid direct in an open trench i.e, trench bed is not rcc of a power house in which rain water, spillage water alwas exists and all power control cables remains submerged even when gas gensets of 480 kw each runningin on load. These power &control cables runs from power house to switchgear room through these trenches in which water remains most of the time. pl explain its merit & de-merit

1882


what is the Connected Load (kW) or Contract Demand (kVA)of mahindra nasik plant??

9499


what is the AC Plant and how can do the work with parts and picture tell us 150 Tr

2033


Why Water motor is not taking a load or pressure while everything is correct. (Note: Motor running properly)

1412


i am studying in final year can i allowed for 23rd UES of Indian army

2124


i need to now what will be the cable size to the following load, transformer to distribution panel distance 110m, load 1000kw, voltage 400v, pf 0.85, permissible voltage drop 2.0%, overhead line, atmospheric temperature 35 degree c.

1634


Is any AC drive(VFD) had a feature of DC injection braking? if available please mention the detail. i.e drive can supply braking torque when the motor in idle state.

2154


what is positive , negative & zero equivalent system resistance

1950


what type questions asked in hp cl

1872


During regenerative breaking= A rotating magnetic field is reversed B slip is positive C torque is positive D slip is negative

2136


I am experienced with house and industrial wiring but I don't have any licence how can I apply an licence and which type of licence i can get i didn't complete deee just only experience

1647


In electrical what is earth(ground)connection, wht is the importance of it, why it is recomended to maitain below 3VAC between Neutral and earthspecially in PLC used machines?

2224


what is the transmission loss for electrical supply? specifically a large shopping complex where the grid is half KM away, what will the % of transmission loss? is there any transmission loss for captive unit generation for above set? thanks

1991


Why choke coil is connected in series with starter in tubelight??why starter is connected in parallel to tubelight??

3390


If a shunt Dynamo has induced emf 100V and 0.4 ohm resistance and battery of accumulator of open circuit emf 110V and 0.5 Ohm resistance are in parallel what is common terminal potential difference?

5251