If i want to build 230kv substation what are the equipments
to be installed?

Answer Posted / karthik.g

if you want to install 230kv substation you need to have
following equipments....
1.100MVA Transfomer
2.220 & 110 CB,CT,PT,Isolator,C&R Panels,LA,Insulator
3.PLCC equipments (if need)
4.110V & 50 V LT Switchgear
5.110V & 50V Battery & Charger
6.steel structure (for equipment erection)
7.120KN Disc Insulators (Normal)
8.Al.Bus Bar
9.Insulator hardware
10.Bolts & NUts
11.Conductor
12.earth wire
13.connectors
14.Marshaling Boxes & junction Boxes

Is This Answer Correct ?    6 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How DC earth leakage currents can be reduced ?

1472


what is the Earth Voltages in Power Plants, Sub-stations, Industries, Residential & Commercial Buildings.

1658


How to select, design,size & calculate for 11 KV/33KV/66KV/132KV/220 KV/440 KV circuit breaker for HT side of transformer protection/HT distribution protection?

2298


What si the d/f b/w KVA & KWH, kvarh & kvar, kwh & kvar phase voltage & line voltage

5594


WHAT IS THE SIGNIFICANCE OF VECTOR GROUPS IN TRANSFORMER? WHAT WILL BE EFFECT WHEN PHASE DISPLACEMENT CHANGES IN TRANSFORMER?WHAT IS THE NEED TO BE PHASE SHIFT CHANGE BETWEEN THE PRIMARY AND SECONDARY WINDING

1340






sir please send me previous year questions of jspl of electrical section through which i could prepare myself fpr the test.

1499


how to find ratio of CT & PT in 66/11kv 12 mva supply system ? explain with calculation.

1883


How to design the NGR Resistance

1616


defination of controlled shunt reactor

1791


What is the ratio of true power to apparent power in an ac circuit?

692


Why PS class CT is always preferred for Differential protection?

1097


what will happen if i connect 12 volt battery with 24 volt battery charger.

1461


A powerplant has 8 gensets operating in grid parallel mode. In one genset sometimes there is pf variation and kvar variation. The plant operates in pf mode. When this variation is observed the load is stable, voltage is also stable, freq and genset speed is also stable. How will you check the functioning of pf card. What shall be the ideal output vdc of the pfc, from there it is input to AVR?

1735


Form S and "c" license application both are same? @ tneb portal

1263


armature winding of dc machine produce alternating emf then it convert in to dc by using commutator.But only we consider armature resistance why don't we consider inductive reactane effect?

1638