what is the difference between current voltage transformer
and current transformer and where it is used?
Answer Posted / ravindra gupta
The CVT is meant for voltage measurement in HVAC system.
Apart from this CVT is used for PLCC communication also.
However current transformer is used for current measurement
in HVAC system.
Is This Answer Correct ? | 5 Yes | 0 No |
Post New Answer View All Answers
what kind of technical test that i need to learn because i have an interview tomorrow.. please someone help me..
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
What is boucholz relay and the significance of it in to the trformer?
What is size 00, 01, 1 etc., in HRC fuse types?
why the India electrical supply transmission loss is high when compare to us
hi every body i am master student in control engineering and my project is slip control in trains i assumed a Dc motore as traction motor but i don't have characteristics of this kind of motor that is used in train. i want from every body if he or she has the characteristics or information about Dc motor that is used in train give me those information or technical characteristics .
HOW MANY TYPES OF FUSE?
Why are the laminations insulated from each other?
USE OF 8 WAY PAN ASSEMBLY
Help need in transformer !? Hello Friends The parameters of 2300/230 v 50hz t/f is R1=0.286 ohm R`2=0.319 ohm Rc=240 ohm X1=0.73 ohm X`2=0.73 ohm Xm=49.2 ohm Secondary Load impedance ZL=0.387+J0.29 solve the exact equivalent circuit with normal voltage across primery.. I know every thing but i cant find CURRENT I1=? and I`2=? Please help me give solution or only Formula please please...
Meaning of ingrace protection for motor.for ex IPXY
what is the meaning of WYE and DELTA in Electric meter?
in battery charging room we find two fuses (one in positive other in negative cables ).why it is so?one fuse is ore than sufficient?
what about GD square and its important for motor design?
Define transfer function?