what are the colour's and their indications in bucholz
relay?

Answer Posted / joshykollam

Your question contains two parts
1. what are the colors of silica gel
Silica gel available in Blue and Orange color
2 what are their indications
While Blue changes to White means it absorbed moisture
Again changed to Redish Pink colour need to Replace.
While Orange changes to white colour it absorbs moisture
Again changes to Green colour need to replace

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to know about the rating(voltage and other) of induction motor if its name plate is missing at the manufacturing site.

2882


ASTM D 3455 - Standard Test Methods for Compatibility of Construction Material with Electrical Insulating Oil of Petroleum Origin has been used for Testing Transformer Oils with a product placed in it. Aged Control Oil has a Power Factor of 0.032% at 100°C. Aged Oil with a Test component has a Power Factor of 0.093% at 100°. Is this increase acceptable? If not why? How much increase is acceptable?

1519


What is the tube exial fan?

1703


I am using submission of two ct in one and half scheme for 67/67N protection. Both CTs star point is grounded separately near ct box.Will two point ground give wrong tripping to 67/67N during fault or no matter.

1653


how to select battery for 15 KVA UPS with formula

2097






why do we use spark detector inside the slip ring brush compartment 0ona slip ring induction motor?

1633


What is time response of the control system?

648


What is the necessary and sufficient condition for stability.

710


which motor have relatively high power factor and what is reason for have high pf? 1.capacitor run motor 2.shaded pole motor 3.capacitor start motor 4.split phase motor

1490


What are chief characteristics of state-space method and its techniques ?

1680


how to copy from plc ge fanuc versamax series,all input and output, adress, and printout.

2049


how are reversing the direction of rotation of dc motor

1267


A 7 storey building has a floor area of 35,000sq.ft on each storey. On the ground floor 11KV electrical sub-station is to be erected. A load of 3kw for every 400sq.ft (p.f is 0.8) is proposed for each floor. fire pump 7.5hp, water pump 5hp, lift 2 nos, each 10hp and 20shop load of each shop is 5kw. calculate a. load each floor b. total load of building c. L.T feeders for aech floor and from transformer to main. d. distribution diagram e. capacity of sub-station/capacitor bank f. line diagram

2384


what is difference between line differential and transformer differential?

1243


we have 3 single phase transformers. how will we generate 6 supply from 3 phase supply input

1660