when a motor is connected in parallel with the existing
motor the pf will change or not?
Answer Posted / naresh chandra jha
it depend which type of notor you are connecting . for
example induction motor will operate in lagging power
factor, synchronous phase modilfier with under excited will
operate in lagging and when it is overexcited it will
operate in leading p.f .
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
i am going to give the JSEB,RANCHI exam for power plant,so i need some samples of papers related to that,so please send me these papers by my mail id.
Either the Armoured Earthing strip of HT 3 core cable have to pass through CB CT or not , why ???
what is kondo syatem in eletrical traction
what are the advantage and dis-advantage of 3 phase 4 wire energy meter?
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
why do you add the load short circuit impedance when considering short circuit amperage. It seems that you should only consider supply. If you need to consider loads and you don't know what loads are to be added , what would be a good sub-transient reactance rating for the loads?
What Should be the value of Vector Surge angle at Tripping and how to calculate it?
Explain mechanical rotational system?
WHY EARTHING NOT NEEDED IN BATTERY IN SUBSTATION
how to extend relay operating timing in 24V dc relay card (without using Timer )
can we synchronize star system generators with delta system transmission line ? and how ?
HI....HOW CAN BE MESARED THE VALVE OF NEUTRAL GROUND RESISTOR WHIC IS LOCATED AT SWICHGEAR ON GENERATOR SIDE....
How much load can take a 16 mm aluminum cable 3 phase
In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes
A 7 storey building has a floor area of 35,000sq.ft on each storey. On the ground floor 11KV electrical sub-station is to be erected. A load of 3kw for every 400sq.ft (p.f is 0.8) is proposed for each floor. fire pump 7.5hp, water pump 5hp, lift 2 nos, each 10hp and 20shop load of each shop is 5kw. calculate a. load each floor b. total load of building c. L.T feeders for aech floor and from transformer to main. d. distribution diagram e. capacity of sub-station/capacitor bank f. line diagram