how the 3phase induction motor is running in 2phase supply
with help of capacitor?
Answer Posted / anjali aravindakshan
If one of the 3 phase supply to the induction motor fails the unbalanced stator currents flow.The voltage across the healthy phases increases by (3)^(0.5) times...bcoz of this overheating of motor takes place..To avoid dis we can make 3 phase induction motor to run on 2 phase supply by connecting a capacitor since capacitor does not allow instantaneous change in voltage..in dis way we can make 3 phase induction motor run on 2 phase supply with the help of capacitor....
Is This Answer Correct ? | 4 Yes | 5 No |
Post New Answer View All Answers
WHAT IS THE TOTAL POWER GENERATION IN CHHATTISGARH?
What was your role in the silicon evaluation/product ramp? What tools did you use?
how to compare with Relay settings for HT< panels, RMU panel, and PSS CSS transformer?? 1) Load amps, 2)Tripping time, 3) CT ratio, 4)Cable size 5) Transformer KVA rating 6) transformer full load amps
What Normal(Tangent) towers and Tension(Cut-point) Towers?
Write the programming software name for LG, SIEMENS,Messung,AB
what is the difference b/w pvc cu conductor and cu breaded wire..?
critically criticize the application of ring main unit in power system
What is “pu” in ee?
I want to calculate how much capacitor we connect to maintain the unity power factor? Is there any formula? Pls give me the answer
In diesel generator how AVR get voltage to excitation. And basic diagram DG EXCITATION CIRCUIT.
(1)The demand for electricity , the amount of renewable generation available, the amount of fossil fuel generation available and the cost of the fossil fuel generation are shown in table below period(hrs) demand(MW) renewable (MW) fossil- fuel(MW) cost of fossil fuel(MW) 00.00 - 01.00 2000 1800 2000 30 01.00 - 02.00 2300 2500 2000 30 02.00 - 03.00 2500 2700 2100 45 03.00 - 04.00 2900 3100 2100 50 04.00 - 05.00 2700 2600 2500 45 05.00 - 06.00 2400 2000 2700 50 06.00 - 07.00 2200 1800 2000 36 07.00 - 08.00 2100 1600 2000 36 Assuming that the renewable generation incurs zero cost, determine an optimal generation schedule(specifying the amount of renewable generation and fossil fuel generation used in each period, the cost for each period and the overall cost for 8 hours.)
If the line voltage is reduced to 75% of its rated value then by what percentage current will reduce ?? 75% 25% 50% no change and why ?
i need to now what will be the cable size to the following load, transformer to distribution panel distance 110m, load 1000kw, voltage 400v, pf 0.85, permissible voltage drop 2.0%, overhead line, atmospheric temperature 35 degree c.
can anybody send me syllabus of rrb section engg (electrical). and also send previous question pepar...
what is the meaning of number in (11, 31, 61,14, etc. CDG11, CDG31, CDG61, DDT32