What is vector group? What is meant by DYN11?Why is it needed?

Answer Posted / strateia

The Dyn11 is interpreted as follows:
D-primary winding is delta connected (i.e the three primary
phase windings within the transformer)
y-the secondary winding is delta connected

11-is a multiplying factor for the phase displacement
between the primary and secondary voltages
i.e. for the Dyn11, phase displacement is
= 11*30degrees
= 330 degrees

Is This Answer Correct ?    10 Yes 31 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How does zener phenomenon differ from avalanche breakdown?

703


what ispositive, negative, zero sequence impedence?

1591


if a 3phase 100kva distribution transformer , 400 v,50 hz, 4-wire system is loaded at 160 k.w mostly 1-phase Lighting & Airconditioning split a.c load what will be the net effect on the power system in terms of voltage, powerfactor, current , efficiency of xformer

1472


What is knee point voltage?

680


From past few months I am getting lagging pf even though sufficient capacitors used in circuit. Where is the problem pls answer

942






Is any AC drive(VFD) had a feature of DC injection braking? if available please mention the detail. i.e drive can supply braking torque when the motor in idle state.

1694


The specific heats of the gas at constant pressure and constant volume are respectively 1.0 kJ/kg K and 0.72 kJ/kg K; the value of R for the gas is

707


Does all the output contacts (N/O as well as N/C) of a Numerical relay operate when relay receives a binary input/inputs or contacts are designated to specific logic input/inputs and only these contacts operate?

1619


A 15 kw squirrel cage motor having a maximum efficiency of 90% on a continuous full load has temperature rise of 42 degrees celcius after 30 min and 52 degrees celcius after 1 hr under the above operation conditions. a) calculate its final steady state temperature rise on continuous load and the heating time constatnt. b) if the motor is operated on a short load for 9 min estimate its temperature rise. c) calculate the maximum overload that can be applied on a short, 9 min rating so that the temperature rise is the same as the final steady state temperature rise on continuous load.

704


why we setting 95 deg and 105 deg in wti and oti of distibution transformer ? give the reson for that ?

2596


In our plant we have installed new MCC with ELR and CBCT which is detecting some leakage current in the system but it leading to some confusion when to check that in which feeder which is drawing current we put off the whole panel itself but still CBCT detecting some leakage current so can anybody ans me , where i am going wrong or how to detect whether its actual leakage or CBCT malfunctioning.

1716


What is the difference between electrical earthing and electrical grounding?

691


1. Can a 12v DC choke operate a 60v/12w PL lamp ? 2. Can a 230v ballast fire / operate a 60v/12w PL lamps.

1770


what is allowed value of zero sequence impedancce of 6.6 kv nuetral earthing transformer ?what is the actual value

1661


the grid connection required for a 50 MegaWatt fotovoltaic powerplant is higher or lower than 35kv (high or medium tension)?

1442