what is the function of series reactor

Answer Posted / k.prakashchandra

wrt my above answer please delete generator,as the output
is controlled by the prime mover.However series reator can
be used for generator when two generators have common
excitation due to failure of one of them.

Is This Answer Correct ?    1 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is difference between Harmonic and Non harmonic Capacitor Bank?

2399


if the load is 80 amp for main fuse and 100 amp for breaker so how can we calculate the cable size (cooper ) .

1675


Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.

1103


how to calculate the breaking capacity of different breakers.

1701


what is meant by residual over voltage & residual earth fault ?

8442






what is per unit calculation?looking for simple and strong explanation thk u

2084


The shot circuit in any winding of transformer result? Explain

799


what is basic difference betmeen normal & flame proof motor??

1489


why we use two slope(differential & restraining) in differential relay.but in busbar protection differential we are using only one slope?please explain

1733


Installation method of self treated earth electrode.

1487


I have a drawing of a wound rotor induction motor for a crane. This crane motor has 5 forward speeds & 5 reverse speed implemented of course with different amount of resistance for each speed setting selected. What has got me scratching around is the fact that 8 of the 10 speed selections switch in uneven (unbalanced) amounts of resistances on each of the 3 connections to the motor's rotor.Can this be possible? I would have assumed this would produce unbalanced rotor currents and therefore vibration in the motor. I would greatly appreciate anyone's comments on this. Many thanks, Confused.

1412


In ups static switch if i gives the supply at output end it will open the circuit in stactic switch or not if it will open then how it operates.

1855


What consists of 2 or more thermocouples to be connented series?

1763


what is mean by PIR in circuitbreaker and give me detail of that?

3099


distribution is maximum done by a)radial b)network c) parallel d)b & c

1497