In a company has been installed an analog amperemeter, this
company was suplied by generator X, there is no problem in
the ampere meter, rigth now this company's supplied by
generator Y then the pointer in amperemeter vibrating. What
happened? Why?
Thank's

Answer Posted / bala

first check x and y same rating d.g if u say yes then check
ct details .and also check any sound varation in your d.g
set

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to carry out Magnetizing Current Test on Distribution transformer and what purpose we are doing this test. why transformer rating in always in KVA ? what ispositive, negative, zero sequence impedence? How ElCB tripping if Neutral touch with ground Why AC & DC capacitor are use in UPS ? why motor rating in KW? how to syncronize two dg sets

1723


what sort of general awareness questions are asked in o.n.g.c entrance exam?????????????????

4214


what ispositive, negative, zero sequence impedence?

1590


would you please give me any idea about the BARC interview question on electrical? i have an interview on 1st july.....plz hlp me.......its urgent......

2029


What is Diff btw Fire Alarm & VESDA System???

1942






54 Comments Alok and Bhanu play the following min-max game. Given the expression N = 38 + X*(Y – Z) where X, Y and Z are variables representing single digits (0 to 9), Alok would like to maximize N while Bhanu would like to minimize it. Towards this end, Alok chooses a single digit number and Bhanu substitutes this for a variable of her choice (X, Y or Z). Alok then chooses the next value and Bhanu, the variable to substitute the value. Finally Alok proposes the value for the remaining variable. Assuming both play to their optimal strategies, the value of N at the end of the game would be?

1781


3ph motor running with unequal kw and different pf what are the reasons

1226


A Generator is in running condition and Rotor earth fault alarm is coming.How to check on line(i.e in running condition) whether there is actual earth fault in rotor or not.

1465


operation of diesel generator

1544


how to get electrical supervisour certificate in gujarat

1534


We need to current density & short circuit calculation at 65kA for aluminium & copper busbar.

1256


What is the reason for using a GE G101 MCB in place of an EP102 MCB if both are capable of AC circuit protection?

2165


What is online and offline ups? how does it works?

1625


Why an ac solenoid valve attract the plunger even though we interchanges the terminal? Will the poles changes?

679


The windings of a transformer are divided into several coils, because?

816