What quedtion to ask a electrical maintenance technician?

Answer Posted / loboreliance2003

Please contact me at williamloboatrediffmaildotcom and I
will send you a list of questions and also you may also
give me a list of your electrical equipment on site for
which you require the maintenance electrician.

Is This Answer Correct ?    5 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why electron produce magnetic field when it is in motion?

1691


USE OF 8 WAY PAN ASSEMBLY

1497


what is the use of static frequency converter and static excitation equipment? and where it is employed? for what?

3047


i need project topics along with circuit diagram in the electrical and electronics engg and also some websites regarding projets.

1579


in india per day how much power is generated including all power station

1460






What do you mean by a phase angel of instrument transformer?

642


How Calculet The UPS AH In Load

1233


Can you explain about TEE protection scheme?

1759


Why single phase induction motors are not self starting ?

1057


How to select the cable and voltage drop in circuit?

1185


Mr. mohh sahid m not satisfied for ur answer to the que weather the size of transformer increases or decreases withchange in fr for more detail go to the answer given by me

1628


If not into production, how far did you follow the design and why did not you see it into production?

1712


Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1.  H1-H2 = H2-H3 H3-H1 2.  H2-H3 = H3-H1 H1-H2 3.  H3-H1 = H1-H2 H2-H3 For the LV side also: 4.  X1-X0 = X2-X0 X3-X0 5.  X2-X0 = X3-X0 X1-X0 6.  X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0  H2-H0  H3-H0    X0-X1  X0-X2  X0-X3 128.0  119.9  7.2      29.2   13.3   15.8 70.7   128.4  59.2     23.4   22.0   3.6 7.2    120.1  128.1    13.4   29.3   15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?

1368


Why the efficiency of a three-phase induction is the motor is less than that of a three-phase transformer?

719


Can u tell me design of switch yard

1697