Why the starting current in Induction Motor is very high as
compared to normal rated current ????
Answer Posted / desingurajan
The emf induced in the rotor depends upon the rotor frequency which further depends on relative speed between rotor and synchronous speed of rotating magnetic field. The relative speed at the time of starting or standstill is maximum and hence large emf in induced in rotor conductors or winding due to which very high current flows in rotor which is generally 5 to 7 times of the full load or running current of an indication motor.
Is This Answer Correct ? | 20 Yes | 6 No |
Post New Answer View All Answers
what you have to see after one week or month from the day of installation of transformer ?
sir i want previous entrance exam papers for written test
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
Write the force balance equation of ideal dashpot element.
two phases with neutral supply can be taken in 3C X 10 sq.mm cable .
i have a 4 Mva transformer 34.5 kv / 480-277 v and i used 2 parallel 3200 amp bus duct for the secondary feeder using 3 ply of bus bar ( 3/8" x 5" ) as a common where the flexible link terminated and 6300 amps breaker for the main, the lower bus duct reaches 70 degrees and the upper bus duct reaches 55 degrees when i used thermal scanner. why the temperature is not balance when the load reaches 3600 amps.
following are the questions asked in interviews: 1) Considering the short circuit fault, which switchgear is preferable, SFU OR MCCB? Which operates faster? whicg one is popular in Indian Market and why? 2)Define SCPD. What is type2 coodination? 3)Why the contactor rating is higher for the fuseless selection than for fuse selection? whether the ratinf of SFU or MCCB remains the same in both the cases? 4)If the HP rating is known then can you calculate the ratings of L.V Switchgear(SFU/MCCB, contactor, OLR) without using the selection chart?
What is the de rating factor of cable? What is the importance of the de rating factor in cable select
WHAT IS THE TECHNICAL SPECIFICATION OF C CURVE & D CURVE LEGRAND MAKE MCB
Describe Non I.S. Earth System and why is it used?
what is the preventive maintence for ht panels and busbars and vcb abd acb's.
Draw a SLD of HT distribution EB grid up to users Transformer?
Why are the laminations insulated from each other?
What is online and offline ups? how does it works?
What is zero of the system?