what is the defination of electrical engineer.

Answer Posted / k.rakesh reddy.

technically thinking to improve the production of
electricity with any loss

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Currently what is the highest capacity (MVA) of SPPg generator available in the market?

1331


in power generator normaly voltagr betwween esth to neutral is 0 but my work place generator show the volatge is 60v any body know why? thanks

1426


what are the effects when a salient pole alternator is run at high speed like 3000 r.p.m?

1942


what is the use of commutator in dc motor if we supply ac ? commutator is used to convert ac to dc.and it is used to arrange the flux in unidirectional in case of dc supply. if we give ac as supply to dc motor what is the use of commutator?

1647


What is the Surge for 1.1 Phase Induction Motor(For Eg.1Hp) 2.3 Phase Induction Motor(For Eg.1Hp) 3.AirConditioner(For Eg 1Ton) 4.Refrigerator(For Eg 180Ltr or 160kW) 5.Induction Cooker 4. Ceiling Fan

1628






Why wind turbines wheels rotate constantly

643


How to measure current and voltage in an ELV circuit

3620


What is the use of oil in transformers?

631


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

1669


how electical engineer is related to apsrtc (general) post? if they ask a question in interview as why did u choose this job what shd be answer

1644


why we are using Load factor?

1368


Why we used 690V in ACS 800 drives.Why dont use standard voltage like 415v or 1.1Kv

1930


What are the advantages of instrument transformer?

637


1600 KVA ka transformer hi aghar lt side par 800A aur voltage 420 ho to HT side ki cable ki rating keya ho gi?

1590


why the starting voltage drop in a cable needs to be limited?what is percentage of the voltage drop allowed during starting?

1364