Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the differance between Digital Energy meter &
Static energy meter? why the KWH diferance between both
meters.

Answer Posted / chirag kakadiya

static energy meter is working on the principle of
electromegnetic indunction and the meter is operated if
certain saturation current pass through the coil which
produce torque in that metal disc and it rotate so some time
if the load on meter is minor so that current passed through
the coil is not enough to produce the torque to rotate the
disc. where as in digital energy meter ,working of energy
meter is through small electronic chip which sense the minor
to minor current pass through it. THIS IS THE DIFFRENCE
between digital and static energy meter and we may better
know that due to this different if minor load is supplied
through the meter than KWH reading diffrence found between
both the meters.

Is This Answer Correct ?    22 Yes 24 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Can we use shunt trip coil instead of trip coil with protection relay for protection?

1745


wat system call?

1977


if i get a drop in my 1st year and the i clear my 2nd year and 3rd year all clear and i dont have any back logs so can i be able to sit in campus selection??

1864


Why L.T.Cable voltage rating is 1.1kV,where as system voltage is 0.415kV?

2351


In case of HV test on medium voltage cables, BS is asking for 4 U0 where as IEC is asking for 3.5 U0. Can any one advise me how this 3.5 times or 4 times U0 is derived?

1702


132/66kv sub-station procation ?

2270


Mention the disadvantages of low power factor? How can it be improved?

1162


wish of these transformer uses oil?

1633


sent to a site and asked to explain how you would like a twenty seven flour building should be supplied with lighting and sockets plus a water boiler.

1966


hi, i have 3x200KVA and 2 x 80KVA UPS with battery bank of 150AH 68Nos. and 100AH 204Nos., i need to install AC either ductable or PAC type, so can you help me to calculate heat load and capacity of the AC to install.

2724


what are the installation procedure of high voltage power transformer,CT,CB&PT?

2084


WHAT IS SHORT CIRCUIT STRENGTH OF 100 AMPS MCCB?

2119


explain comutator action in detail.thanks

2263


HOW TO CALCULATE HV TEST VOLTAGE FOR ELECTRICAL EQPT.

2226


what is the requirement regarding earthing of Single conductor with AWA

2260