Answer Posted / dinesh kakatkar
for the control of any circui few amperes of current is
required so normally we use a small cross-sectional wires.
This current can be mA to Few Ampers and risk of FAULT
current flowing is less and normally a single phase so we
require a small cable of 2 core or 3 core or less cross-
section.
The power cables is used depending on the application in
the Amperes to KA and the FAULT current is more and in the
range of KA.So the application of this cable is to supply a
several Ampere of current and Voltage ranging from the 230
V to Several KV depending on the load.So this cable is
called power cable as it is used to feed power.
Even based upon the application the cables are called as
Power and Control Cables.
Is This Answer Correct ? | 6 Yes | 1 No |
Post New Answer View All Answers
What is difference and reason b/w -48V BTS system and 24 V BTS system. Plzzzzzzzzz tel me.
ult of expression 'document.FrmQF.myem
Some times to change of DOR of a motor, interchange of R & B is not effected and RYB take same current, but interchange of R&Y is effected ie change the DOR. My doubt is what is the problem in motor and how it is happen.
How do u analyse protection fault when vcb tripping on load
CAN CU XLPE/PVC CABLE BE USED INPLACE OF LOW NOISE SCREENED CABLE? KINDLY GIVE REASONS
while starting a liquid starter ,is there any volage drop on water/soda on tank.can we touch the tank on starting?
how can i get the formula to find out the cable size if i know the load of main fuse protection.
write encoder 17 pins details? pin a;b+, pin b;w+,..pin s & t. what is the meaning of b+, w+? explain;
while doing high voltage test on 11kv/433 distribution transformer why we only give 28 kv on hv side and 3kv on lv side for power transformers what is the value what factors it depends
How can I calculate per unit (KWH) fuel (Gas/ Diesel both) consumption 1MW unit?
what is reverse power relay brief explanation and in b/w where it is connected
. How to calculate the Short Circuit Impedance in Transformer? How to calculate the Short Circuit Impedance in Transformer?
During Starter Panel Com missing I Found The Main Incomer 40Amp MCB 10KA Trip When Motor Change Star To Delta Motor Rating 20HP BUT When We Use Same MCB To Other Motor It Does Not trip Or What Is Necessaries for Star Delta Starter MCB SFU MPCB OR MCCB And What are The Breaking Capacity of MCCB in the Motor above 15HP
What are the three constants associated with a steady state error?
Which type of motor is used in trains, what is the rating of supply used explain working principal?