no of rotrs poles in salient pole synchronous machine
Answer Posted / akshay gupta
It depends on the Speed of the Synchronous Motor,Minimum
number of Poles is 2, so maximum speed of a Synchronous
Motor in India(Where working Frequency is 50Hz)can be
3000rpm.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
What is the unit of charge and current?
how rectifier transformer work in electroststic precipetatore(esp?
Draw a SLD for main panel for school having connected load of 1200kw and emergency generator 200kw.also show the increase of additional load of chiller 225kw in the lv panel indicating meter postion size of transformer ,cables and capacitor bank.
Can the output voltage of a rectifier be greater than the input AC voltage without the use of any voltage multiplier in the circuit??please provide the explanation too..
Is there any specialised book to refer about fault level calculation both in MV and LV side??
how can i reduce sparking without stepdowning the voltage
what is the correct format to create a resume for interview??
how can we make cable shedule for controll wiring ? which details must be required for it.?
when ac current flows thru d coil of a contactr,it energizes,magnetic field attracts d contact of the coil...nw wont dt ac current in d contct induce current back on to d coil thru mutual inductance leading to high currnt in d coil
Zone of protection and tripping scheme of arc protection relay.
Please sent me some previous year question papers of BSNL-JTO telecom and RRB in ELectrical Engineering to varshashahi@yahoo.com
my question is how to answer the question "you are from b.tech eee background and why do you want to go for banking
Give some differences between open loop and closed loop?
We are preparing another project which involves Waste heat recovery from a 1 MW GE Engine. The Engine in particular gives out flue gas at 487Deg C with a flow rate of 5650 kg/hour and this can be cooled to 180 Deg C. This gives a thermal output of ~ 594 KW that is available for input to VAM via heat exchanger / boiler. Additionally 581 KW will be available from engine jacket water (temperature profile 80/ 80 Deg C and a flow rate of 50m3/hr) Our estimation is that 300 TR of cooling is possible with a suitable VAM machine(s). Please advise what is the most suitable arrangement with maximum TR and min Capital expenditure. plz reply me as early as possible
In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes