Answer Posted / magesh

All who said as Centrifugal Pump, just cheer up guys.
Centrifugal Pump is always used in Boiler feed pumps.
Because with the usage of centrifugal pump, we can get a
constant pressure with varying flow.
This must be well understood. Because at different load
conditions( if coal input is lesser at some times) then the
feed water input must also be decreased, so centrifugal
pumps are used. With the use of Centrifugal pumps we can
vary the flow. But we can keep the constant pressure.

Is This Answer Correct ?    14 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

When maximum discharge is obtained in nozzle ?

631


what is heat treatment and why is it done?

654


how we can calculate natural vibration frequency for steam turbine rotor please.

3327


What is meant by indirect contact heat exchanger?

592


What is meant by laminar flow ?

673






A simple problem involing in hoops stress. For sphere: M= [3/2]*p*V*[density of pressure vessel material/Maximum working stress it can tolerate] For Thin walled pressure walls: Hoops stress or stress in the radial direction =p*r/2t ?

2211


Who all falls under the Perview of Excise Duty, we mean who has to pay the Excise Duty, eg: does all mfrs have to pay ED or who has high turnover they should only pay ED, if yes that what is the Turnover limit?

1374


What does 0.125 inch stand for in 0.125 inch npt thread?

514


i am a mechanical engg.8th sem student.i want to know the syllabus and criteria,previous question paper set of section engg(RLY).please send it to my email id.pleaseeeeeeeeeeeeeeeeeeeeeee

1564


Explain the difference between self-energizing and self-locking in brake / clutch.

4812


What is the difference between newtonian and non-newtonian fluids?

608


How do you reset the circuit breaker?

1443


why we do not megger to motor under system is very high vaccum condition. and what is the tempreture of vaccum conditon

1562


How much should be the minimum and maximum suction and discharge pressure of screw chiller plant.

2321


What is shearing?

640